Parameters
Value
EL RANGE
0
EL LOST
0
NO MOTOR
0
NO
0
SENSOR
ELEV
175
ZERO
ELEV MAX
25
LAST
0
DECK
LAST BELT
0
LAST
0
MOTOR
MASTER
---
PIN
Maintenance Mode
Highest
Option 1
Value
255
---
255
---
255
---
255
---
242
---
170
---
65565
---
65535
---
65535
---
---
13579
Option 2
Default
Value
---
0
---
0
---
0
---
0
---
240
---
57 = 120V
Black motor
25 = 120v
Silver motor
80 = 230V
---
0
---
0
---
0
13579
13579
Meaning
# of times elevation
range was detected.
(EL Range will detect
between the Pot read
of 253 and 255).
# of times elevation
range was detected.
(EL Lost will detect
when the display has
lost the elevation
motor Pot reading).
# of times No Motor
was detected.
(display when there's
no motor current
detected, but there is
belt movement).
# of times No Sensor
was detected.
(No Sensor will
display when there's
no RPM feedback).
Voltage to elevation
motor to obtain 0%.
Multiply by 0.0196608
to = actual voltage.
Voltage to elevation
motor to obtain 15%.
Multiply by 0.0196608
to = actual voltage
# of miles when the
deck was last waxed.
After a 2000 mile (or
3000 KM) difference,
"REWAX BELT" will
scroll in the display
until "LAST DECK"
miles are updated.
# of miles when the
last running belt was
replaced.
# of miles when the
last motor was
replaced.
Master pin personal
trainer configuration.
15