Time and Date Functions

• Master Code+[#] + [6] [3], or if programmed, press the designated function key.
Viewing the
• The system lets you view its time and date setting.
Time and Date
• The display remains on for about 30 seconds.
To Set the
• A cursor appears under the first digit of the hour.
Time and Date

Event Log

The system records up to 254 events in a history log, which can be viewed by the master user using an Alpha Display keypad.
• Master Code+ [#] + [6] [0]
To view the
• The system displays the most recent event as follows:
Event Log
• When the log is full, the oldest event is replaced by the logging of any new event.
• Refer to the Event Log Codes Table below for the meanings of the various codes.
• Press any key other than [∗] or [#]
Exit Event Log
Event Log Codes Table
Code
Definition
110
Fire Alarm
121
Duress
122
Alarm, 24-hour Silent
123
Alarm, 24-hour Audible
131
Alarm, Perimeter
132
Alarm, Interior
134
Alarm, Entry/Exit
135
Alarm, Zone Type 5
143
Alarm, Expansion Module
144
Sensor Tamper Alarm
145
ECP Module Cover Tamper Alarm
146
Silent Burglary Alarm
150
Alarm, 24-Hour Auxiliary/Monitor zone
162
Gas Alarm
301
AC Power
302
Low System Battery/Battery Test Fail
305
System Reset (Log only)
321
Siren Supervision Failure
333
Trouble, Expansion Mod. Supervision
341
Trouble, ECP Cover Tamper
344
RF Receiver Jam
351
Telecom Line Fault
353
Alternative Comm. Media Trouble
354
Failure to Communicate (log only)
373
Fire Loop Trouble
374
Exit Error Alarm
380
Trouble Zone Type 5
381
RF Supervision Trouble
382
Supervision Auxiliary Wired Zone
(sent after code 333 is sent)
383
RF Sensor Tamper and Double-Balanced
Zone Tamper
384
RF Sensor Low-battery
393
Clean Me (ESL smoke detectors only)
• Master Code+[#] + [6] [3], then press [∗] while the time/date is displayed.
NOTE: To move cursor ahead, press [∗]. To go back, press [#].
• Enter the 2-digit hour setting; enter the 2-digit minute setting.
• Enter the last two digits of the current year.
• Enter the 2-digit month setting (01-12); enter the 2-digit day setting (01-31).
• Press [∗] to accept the settings and continue.
The Clock Adjustment prompt is displayed. This prompt lets you add or subtract up to 59 seconds per
day, if needed, to keep the real-time clock accurate.
• Press [0] to add seconds per day, or press [1] to subtract seconds per day.
• Enter the desired number of seconds per day (01-59) to add or subtract.
• Press [∗] to accept the settings and exit. This mode automatically exits after 10 seconds.
Pressing [∗] displays previous events (back in time).
001 E441 U001 P1
Pressing [#] displays events forward in time.
13:38 21/06/02
event number, type of event, identified by its corresponding code, displayed in chronological order, from
most recent to oldest.
zone or user number (depending on type of event), partition in which event occurred,
time and date of the event's occurrence.
Code
Definition
401
Disarmed, Armed AWAY,
Armed MAXIMUM
403
Schedule Arm/Disarm AWAY
406
Cancel by User
407
Remote Arm/Disarm (Downloading)
408
Quick Arm AWAY
409
Keyswitch Arm/Disarm AWAY
412
Successful Download/Access
441
Disarmed/Armed STAY/INSTANT,
Quick-Arm STAY/INSTANT
442
Keyswitch Arm/Disarm STAY
461
Wrong Code Entry (keypad lockout activated)
570
Bypass
601
Manually Triggered Dialer Test
602
Periodic Dialer Test
606
Audio Alarm Verification (AAV) to Follow
607
Walk Test Entered/Exited
623
Event Log 80% Full
625
Real-Time Clock was Changed (log only)
626
Time/Date Inaccurate
627
Program Mode Entry (log only)
628
Program Mode Exit (log only)
750 -
Reserved for Configurable Zone Type report
789
codes (check with central station when using
these codes)
801
Override Tamper Arming (log only)
802
Override Low Battery Arming (log only)
803
Override AC Loss Arming (log only)
804
Override Supervision Fail Arming (log only)
999
Non-Alarm Zone Type (Zone Type 23) Fault
(log only)