Kenwood TK-780 Service Manual Supplement page 56

Hide thumbs Also See for TK-780:
Table of Contents

Advertisement

TK-780/H
Item
Condition
11. Fine LTR
1) Set test mode
Select "FLTR" in tuning mode. Deviation
"L FLTR"
deviation meter filter
LPF : 3kHz
HPF : OFF
PTT : ON
2) "C FLTR"
PTT : ON
3) "H FLTR"
PTT : ON
12. DTMF
1) Set test mode
deviation
Select "DTMF" in tuning mode.
Deviation meter filter
LPF : 15kHz
HPF : OFF
PTT : ON
13. MSK
1) Set test mode
deviation
Select "FMSK" in tuning mode.
Deviation meter filter
LPF : 15kHz
HPF : OFF
PTT : ON
14. TONE
1) Set test mode
deviation
Select "TONE" in tuning mode.
Deviation meter filter
LPF : 15kHz
HPF : OFF
PTT : ON
56
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Power meter Rear
ANT
panel
meter
Oscilloscope
AF VTVM Front
MIC
AG
panel
Adjustment
Parts
Method
1.0kHz (Wide)
50Hz (Wide/Narrow)
0.75kHz (Narrow)
3.0kHz (Wide)
0.2kHz (Wide)
1.5kHz (Narrow)
0.1kHz (Narrow)
3.0kHz (Wide)
0.1kHz (Wide/Narrow)
1.5kHz (Narrow)
3.0kHz (Wide)
0.1kHz (Wide/Narrow)
1.5kHz (Narrow)
Specifications/Remarks