SPECIFICATIONS· GENERATOR 11.5/9.2KW ETD
AG GENERATOR (Single Phase)
AG GENERATOR (3 Phase)
Single Phase
Brushle", four pole, revolving field.
Three Phase
Brushless, six-pole, revolving field. Sealed
Pre-lubricated, single bearing design.
11.5 KW - 60 Hertz
lubricated, single-bearing design. 12 Lead
Reconnectable, single phase transformer
9.2 KW - 50 Hertz
reconnectable for low voltage ME, high
regulation (opuonal solid state voltage
voltage Delta. Solid state voltage regulator with
regulator)
protection circuitry
Voltage
120 or 120/240 volts - 60 hertz
Voltage - 3 phase
Low Voltage WYE
240 Volts
230 Volts - 50 Hertz
(60 Hertz)
High Voltage WYE
480 Volts
Voltage Regulation
±5% no load to full load.
DELTA
240 Volts
frequency Regulation
.3.Hertz
(.5%)
no load to full load.
Voltage - 3 Phase .
High Voltage WYE
400 Volts
(50 Hertz)
DELTA
230 Volts
Rating (Volts AC)
Amperage - 3 phase
Low Voltage WYE
34 Amps
60 Hz (1 BOO rpm)
120 volts
95.8 amps
(60 Hertz)
High Voltage WYE
17 Amps
11.5 KW
120/240 volts
95.8/47.9 amps
DELTA
34 Amps
50 Hz (1500 rpm)
230 volts
40 amps
Amperage - 3 phase
High Voltage WYE
16 Amps
9.2KW
(50 Hertz)
DELTA
29 Amps
Generator Cooling
225 - 250 cfm (5.66 - 6.37 cmm)
Generator Cooling
225 - 250 cfm (5.66 - 6.37 cmm)
Air requirements
Air requirements
(60 Hz) at 1800 rpm
NOTE: Increase air supply 15% for 50 Hertz
(60 Hz) at 1800 rpm
NOTE: Increase air supply 15% for 50 Hertz
operation (1500 rpm)
operation (1500 rpm)
Generator Compartment
122'f (50'C) maximum
Generator Compartment
122'f (50'C) maximum
AmbientTemperature
Ambient Temperature
Recommendations
NOTE: Forced ven#lation should be provided
Recommendations
NOTE: Forced ventilation should be provided
to maintain generator compartment
to maintain generator compartment
temperatures below 122'F (50'C).
temperatures below 122'F (50'C).
SPECIFICATIONS· GENERATOR 12.6110.4KW ETD
AC GENERATOR (Single Phase)
AC GENERATOR (3 Phase)
Single Phase
Brushless, four pole, revolving field.
Three Phase
Brushle", six-pole, revolving field. Sealed
Pre-lubricated, single bearing design.
12.5 KW - 60 Hertz
lubricated, single-bearing design. 12 Lead
Reconnectable, single phase transformer
10.4 KW - 50 Hertz
reconnectable for low voltage WYE, high
regu~tion
(optional solid state voltage
voltage Delta. Solid state voltage regulator with
regulator)
protection circuitry
Voltage
120 or 120/240 volts - 60 hertz
Voltage - 3 phase
Low Voltage WYE
240 Volts
230 Volts - 50 Hertz
(60 Hertz)
High Voltage WYE
480 Volts
Voltage Regulation
±5% no load to full load.
DELTA
240 Volts
frequency Regulation
.3 Hertz
(.5%)
no load to full load.
Voltage - 3 Phase
High Voltage WYE
400 Volts
(50 Hertz)
DELTA
230 Volts
Rating (Volts AC)
Amperage - 3 phase
Low Voltage WYE
38 Amps
60 Hz (1800 rpm)
120 volts
95.8 amps
(60 Hertz)
High Voltage WYE
19 Amps
12.6KW
120/240 volts
195.8/49.9 amps
DELTA
3BAmps
50 Hz (1500 rpm)
230 vol'"
40 amps
Amperage - 3 phase
High Voltage WYE
18 Amps
10.4KW
(50 Hertz)
DELTA
32 Amps
Generator Cooling
225 - 250 cfm (5.66 - 6.37 cmm)
Generator Cooling
225 - 250 ctm (5.66 - 6.37 cmm)
Air requirements
Air requirements
(60 Hz) at 1800 rpm
NOTE: Increase air supply 15% for 50 Hertz
(60 Hz) at 1800 rpm
NOTE: Increase air supply 15% for 50 Hertz
operation (1500 rpm)
operation (1500 rpm)
Generator Compartment
122'f (50'C) maximum
Generator Compartment
122'f (50'C) maximum
Ambient Temperature
Ambient Temperature
Recommendations
NOTE: Forced ventilation should be provided
Recommendations
NOTE: Forced ventilation should be provided
to maintain generator compartment
to maintain generator compartment
temperatures below 122'F (50'C)).
temperatures below 122'F (50'C).
Engines
&
Generators