SPECIFICATIONS - GENERATOR 10.7
n
.SKW EDT
AC GENERATOR (Single Phase)
AC GENERATOR (3 Phase)
Single Phase
Voltage
Voltage regulation:
Frequency regulation:
Rating (Volts AC)
60 Hertz (1800 rpm)
10.0KW
50 Hertz (1500 rpm)
7.5KW
Generetor Cooling
Brushle". four-pole, revolving field.
Pre-lubricated, single-bearing design.
Reconnectable, single-phase transformer
regulation (optional solid-state voltage
regulation).
120 or
120/240
Volts - 60 Hertz
230 Volts - 50 Hertz.
±5% no load to
full load.
.5 Hertz (.60%) no load to full load.
120 Volts
83.3 Amps
120/240
Volts
83.3/41.6 Amps
230 Volts
22.6 Amps
225 - 250 cfm (5.66 - 6.37 cmm)
Air Requirements(60 Hertz) at 1800 rpm
NOTE:
Increase air supply 15% for 50 Hertz operation (1500 rpm).
Engine Compartment
100 - 200 cfm (2.83 - 5.66 cmm)
Three Phase
10.0 KW· 60 Hz
7.5 KW· 50 Hz
Voltage - 3 phase
(60 Hertz)
Voltage - 3 Phase
(50 Hertz)
Amperage - 3 phase
(60 Hertz)
Amperage - 3 phase
(50 Hertz)
Engine Compartment
Generator Cooling
Air Requirements
(60 Hertz) at 1800 rpm
Brushless, six-pole, revolving field. Sealed
lubricated, Single-bearing design.
12
Lead
reconnectable for low voltage WYE, high
voltage Delta. Solid state voltage regulator with
protection cirCUitry
Low Voltage WYE
240 Volts
High Voltage WYE
480 Volts
DELTA
240 Volts
High Voltage WYE
400 Volts
DELTA
230 Volts
Low Voltage WYE
35 Amps
High Voltage WYE
15 Amps
DELTA
30 Amps
High Voltage WYE
14 Amps
DELTA
24 Amps
100 - 200 efm (2.83 - 5.66 cmm)
225 - 250 elm (5.66 - 6.37 cmm)
Generator Compartment
122°F (50°C) maximum
NOTE:
Incraase air supply 15% for 50 Hertz operation (1500 rpm).
Ambient Temperature
Recommendations
Generator Compartment
122°F (50°C) maximum
Ambient Temperature
Recommendations
8.0/6.0KW EDT
AC GENERATOR (Single Phase)
Single Phase
Voltage
Voltage regulation:
Frequency regulation:
Rating (Volts AC)
60 Hertz (1800 rpm)
8.0KW
50 Hertz (1500 rpm)
8.0KW
Generator Cooling
Air Requirements
(60 Hertz) at 1800 rpm
Brushless, four-pole, revolving field.
Pre-lubricated, Single-bearing design.
Reconnectable, Single-phase transformer
regulation (optional solid-state voltage
regulation).
120 or 1201240 Volts - 60 Hertz
230 Volts - 50 Hertz.
±5% no load to full load.
.5 Hertz (.60%) no load to full load.
120 Volts
66 Amps
120/240
Volts
66133
Amps
230 Volts
22.6 Amps
175 - 200 elm (4.95 - 5.66 cmm)
NOTE:
Increase air supply 15% for 50 Hertz operation (1500 rpm).
Engine Compartment
100 - 200 elm (2.83 - 5.66 cmm)
Generator Compartment
122°F (50°C) maximum
Ambient Temperature
Recommendations
Engines & Generators