INSTALLATION
General
Proper location and installation of the generator set in the vessel
are of prime importance.
Factor s
in the installation that must be considered are ventilation
for
the
generator
for
proper
cooling
and
engine
combustion
air;
exhaust
system
to properly discharge
raw cooling water,
quiet the
exhaust
and expel
exhaust
gas;
cooling
water
supply;
fuel
supply;
and electrical connections.
Factors in the location that must be considered are proper
support
and access
for
serv icing
and repair s.
These
factor s will be dis-
cussed in this manual.
(1/2"
Mounting Holes)
There are four 1/2-inch bolt holes in each generator mounting rail to
properly secure the generator to its mounting platform.
Location
The location
should
be
such that it
is ..9!..,y,
above low-lying
vapor
areas, and away from being splashed by bilge water or water from above.
It should be properly ventilated and accessible for minor
servicing
and repairs.
Access for major repairs should be given consideration
as well.
The
location must be properly ventilated to provide the
fresh
cooling air
for
the generator
end and for
engine combustion.
Hot generator discharge air must be removed from the generator area.
The platform on which the generator is mounted should be strong enough
to
support
the
generator
and
securely
hold
the
mounting
rails
fastened to it at all angles of vessel operation.
7