Westerbeke BTG-9KW Operator's Manual page 45

Marine gasoline generator set
Table of Contents

Advertisement

4-Pole
Generator Voltage
Load
Speed
Frequency l20V (110) 240V (220)
Applied
(rpm)
(Hertz)
plants
Plants
None
1830
62
122
244
(1530)
(52 )
(112 )
(224 )
Half
1800
60
120
240
(1500)
(50)
(110)
(220)
Full
1755
59
110
220
(1455 )
(49 )
(100)
(200 )
The output voltage should be checked periodically to ensure proper
operation of the generating plant and the appliances it supplies.
If an AC voltmeter or ammeter is not installed to monitor voltage and
load, check it with a portable meter and amprobe.
Preventive Maintenance
Maintenance on the generator is minimal.
Keep the generator clean, dry and well-ventilated.
Ensure all connections are clean and tight and that cables carry-
ing
AC
voltage
are
properly
supported
and
protected
against
chaffing.
The rear armature bearing is lubricated and sealed; therefore, no
maintenance is required.
If the bearing becomes rough or noisy,
replace it.
General Troubleshooting
A complete
and
illustrated
text
on
troubleshooting
the
9
KW BTG
Generator
is
furnished
in
the
Technical
Manual
that
is
available
through your local dealer.
39