Westerbeke BTD 8.0 KW 60Hz Operator's Manual page 35

Diesel, single and three phase generators
Table of Contents

Advertisement

SYSTEM SPECIFICATIONS CONTINUED ...
General - 3 Phase
12.5 A KW - 60 Hertz
9.3 A KW - 50 Hertz
Voltage - 3 Phase (60 Hertz)
Voltage - 3 Phase (50 Hertz)
Amperage - 3 Phase (60 Hertz)
Amperage - 3 Phase (50 Hertz)
AC GENERATOR:
ENGINE COMBUSTION AIR
REQUIREMENTS
(60 Hertz) AT
1800
rpm
ENGINE COMPARTMENT COOLING
AIR
TUNE UP SPEC/FlCA TIONS
INJECTOR
PRESSURE
ENGINE TIMlNG
Brushless six pole. revolving field. Sealed lubricated
single bearing design. 12 Lead reconnectable for
low voltage
WYE.
high voltage Delta. Solid State
voltage regulator with protection circuitry.
Low voltage
WYE
208 volts
High voltage
WYE
480 volts
DELTA
240 volts
High voltage
WYE
380 volts
DELTA
220 volts
Low voltage
WYE
43 Amps
High voltage
WYE
18 Amps
DELTA
37 Amps
High voltage
WYE
17 Amps
DELTA
30 Amps
32 cfm (.906 cmm)
100-200 cfm (2.83 - 5.66 cmm)
1707 psi (120 kglcm 2
+
10 kglcm 2 - 0 kglcm 2 )
33