MIDI CONTINUOUS CONTROLLERS
Pitch Bypass
The unit responds to the following message values for
changing between Manual and Automatic modes.
Parameter Data Range
cc #26
0 -127
0 - 63
off
64 -127
on
The Pitch Bypass key is a toggle type switch.
The message that is sent out is dependent on the current
state. If Pitch Bypass is on, a button press turns off
Pitch Bypass and sends the Pitch Bypass off message.
Adaptive Low Cut key
The unit responds to the following message values for
turning the Adaptive Low Cut function on and off.
Message is sent out and responds in the same way.
Parameter Data Range
cc #30
0 -
2
0
off
1
fixed
2
adaptive
3 -127
reserved
Adaptive Low Cut Filter
Parameter Data Range
cc #31
0 -127
0
50 Hz
126
247 Hz
127
250 Hz (in fixed mode)
127
infinity (in adaptive mode)
24
De-ess key
The unit responds to the following message values for
turning the De-Ess function on and off.
Parameter Data Range
cc #27
0 -127
0 - 63
off
64 -127
on
The De-ess key is a toggle type switch. The message
that is sent out depends on the current state.
If De-ess is on, a key press turns off De-ess and sends
the De-ess off message.
Parameter Data Range
cc #27
0 -127
0
off
127
on
De-ess Control
Parameter Data Range
cc#28
0 -127
0
very little ess reduction
-
-
-
127
no esses left
Correction Amount
The unit will send this message, but not respond to it.
This will be used by the PC program for display
purposes.
Parameter Data Range
cc#19 MSB
0 -3FFFh
cc#51 LSB
MSB
LSB
00
00h
40
00h
7F
7Fh
-200 cents
0 cents
+200 cents