Hitachi SJ100 Instruction Manual page 83

Sj100 series
Hide thumbs Also See for SJ100:
Table of Contents

Advertisement

Func.
Name /
Code
SRW Display
A_11 O/OI–L input active
range start frequency
IN EXS
000.0Hz
A_12 O/OI–L input active
range end frequency
IN EXE
000.0Hz
A_13 O/OI–L input active
range start voltage
IN EX%S
A_14 O/OI–L input active
range end voltage
IN EX%E
A_15 O/OI–L input start
frequency enable
IN LEVEL
A_16 External frequency
filter time constant
IN F-SAMP
Multi-speed and Jog Frequency Setting
The SJ100 inverter has the capability to store and output up to 16 preset frequencies to
the motor (A_20 to A_35). As in traditional motion terminology, we call this multi-speed
profile capability. These preset frequencies are selected by means of digital inputs to the
inverter. The inverter applies the current acceleration or deceleration setting to change
from the current output frequency to the new one. The first multi-speed setting is dupli-
cated for the second motor settings (the remaining 15 multi-speeds apply only to the first
motor).
The jog speed setting is used whenever the Jog command is active. The jog speed setting
range is arbitrarily limited to 10 Hz, to provide safety during manual operation. The
acceleration to the jog frequency is instantaneous, but you can choose from three modes
for the best method for stopping the jog operation.
"A" Function
Description
The output frequency corre-
sponding to the analog input
range starting point
The output frequency corre-
sponding to the analog input
range ending point
The starting point (offset) for
the active analog input range
000%
The ending point (offset) for
the active analog input range
100%
Two options; select codes:
00... Use offset (A_11 value)
01... Use 0 Hz
0Hz
Range n = 1 to 8, where n =
number of samples for avg.
8
SJ100 Inverter
Defaults
Run
Mode
–FE
–FU
–FR
Edit
(CE)
(UL)
(Jpn)
0
0
0
0
0
0
100
100
100
01
01
8
8
3–11
Units
0
Hz
0
Hz
0
%
%
01
8
Sam-
ples

Hide quick links: