To manually bypass a clogged black (i.e. K) jet, perform the following steps:
Main Menu
Load Media
Feed Media Menu
Cut
Pause
Reset
Utility Menu
Prime
Display Settings
Access Cartridge
Print Settings
Color Calib Menu
Service Menu
Calibration Menu
Calibration Menu
Open Jet Menu
Use Calib X/Y
Paper Axis Test
Color Db Menu
In the example below the Magenta jets are illustrated completely blown (100%
filled blocks), but are being automatically bypassed by the printer. There is no
need to manually bypass any of the jets seen here. As long as the printer still
supports a desired print pass mode (refer to top of Prime pattern) then printing
may continue as normal. If the cartridge is still under warranty (<500 ml) and
more than 10 jets are blow, as observed in the Prime pattern, then this qualifies
as a cartridge replacement.
Setup Menu
Utility Menu
Exit
Press Next Option until
clogged jet number is
displayed, press Toggle Jet
Paper Axis
to turn jet OFF, press OK.
Exit
Blown Jets
NovaJet 800 Series Training Guide
Open Jet Menu
Black Edit List
Print Jet List
Cyan Edit List
Clear List Menu
Magenta Edit List
Yellow Edit List
Exit
Black Edit List
Paper Axis
Toggle Jet
Next Option
#
1: On
Prev Option
Ok