6.
Attach dryer brackets and install dryer plenum.
Note: align the dryer plenum guide pins with the dryer brackets.
7.
Secure dryer logic cable and power cord.
universal dryer (black metal) ensure the underside voltage selector switch
is set to either 115VAC or 230VAC depending on region.
8.
Activate diagnostics 'legs test'.
Ensure media rollers and dryer function normally. Both rollers should initially pulse in
one direction. By blocking either the top sensor or bottom sensor path the opposite
roller should reverse direction. Dryer should intermittent pulse every few seconds,
after 5 minutes the air leaving the dryer should be warm.