Wall-mounting
IMPORTANT: Before drilling into any wall ensure no electrical
cables are present in the area.
In order to wall mount your convector please proceed as follows:
1. Fix two brackets "C" following carefully the dimensions as indi-
cated in description (fig. 3). Use a 6 mm masonry drill and suit-
able wall plugs and appropriate two screws and two brackets
(provided).
2. Hang the convector on the two brackets fixed to the wall and
insert metal bracket "D" into the bottom rear section of the
base of the convector as indicated in figure 4.
Mark the positions for fixing these brackets to the wall.
(This bracket when fixed retains the base of the convector in a
fixed position, preventing removal.)
3. Remove the convector heater from the hanging brackets and
drill the wall and insert the brackets.
4. Fit the convector to the 2 brackets "C". Insert Bracket "D" to
the convector base and fix bracket "D" to the wall plug using
the screw (screws and brackets provided).
Your convector is now wall mounted.
The appliances should not be installed directly under a
wall power socket. Do not use your heater in a bathroom.
The appliance should not be installed immediately below a
permanent mains outlet.
Position the appliance so that the plug and the outlet can
be easily reached even after installation.
MAINTENANCE
Always pull the plug out of its electrical outlet before beginning any
cleaning.
This electric convector requires no special maintenance. All you have
to do is dust it off with a soft, dry cloth — but do so only when the
appliance is cold. Never use abrasive powders or solvents.