Accu Scan 250™
1. Mirror - This is a highly reflective surface mirror specifically designed
to optimize and enhance beam output. Never use glass cleaners that
contain ammonia to clean the surface of the mirror (such as Windex).
2. Lens Assembly - This high quality lens is a fully focusing. Focus
the lens by manually turning the lens in a clockwise or counter-clock-
wise direction until the desired effect is achieved.
3. Digital Display - This display shows the menu and operating func-
tions that you can choose from.
4. Mode/Enter Button - This button is used to select and confirm a
function when working in the system menu.
5. Down Button - This button is used to scroll backwards when navi-
gating through the system menu.
6. Fuse Holder - This housing stores a 8 amp (4 amp 220v) GMA pro-
tective fuse. Never defeat the fuse, the fuse is designed to protect the
electronics in the event of severe power fluctuations. Always be sure
to replace the fuse with an exact match as the one being replaced,
unless otherwise told to do so by an authorized American DJ
technician.
7. Power Cord Inlet - This unit is equipped with a removable I.E.C.
power cord. Be sure to only use the power cord included with the
unit, this cord is designed to match the electrical requirements of the
unit. Other cords may cause the unit to overheat or malfunction. Volt-
13
age may vary from venue to venue, when connecting this unit to a
power supply be sure to connect to a matching power outlet. Never
12
use this fixture if the ground prong has been removed or broken off.
The ground prong is designed to reduce the risk of fire or electrical
11
shock in the event the unit suffers from an internal short.
8. Lamp Assembly and Access Plate - This plate accesses the lamp
socket assembly. The unit includes a spring mounted ZB-MSD250/2
250w discharge lamp. Be sure to only replace with same type lamp.
10
After replacing a lamp be sure the lamp is centered in the reflector. See
9
page 32 for details on installing and optimizing replacement lamps.
8
Never operate this unit with the lamp exposed, this lamp emits strong
UV radiation.
7
9. XLR DMX Input Jack - This jack is used to receive an incoming
American DJ
®
Controls and Functions
- www.americandj.com - Accu Scan 250™ Instruction Manual Page 8
service
®