Maintenance; Preparing The Icemaker For Long Storage - Hoshizaki KML-351MAH Service Manual

Low-profile modular crescent cuber
Hide thumbs Also See for KML-351MAH:
Table of Contents

Advertisement

12) Remove the front panel.
13) Repeat steps 18 through 31 in "1. Cleaning Procedure" two times to rinse thoroughly.
14) Move the control switch to the "ICE" position.
15) Replace the front panel in its correct position.
16) Clean the storage bin with water.
17) Turn on the power supply, and start the automatic icemaking process.
B. Maintenance
1. Stainless Steel Exterior
To prevent corrosion, wipe the exterior occasionally with a clean and soft cloth. Use a
damp cloth containing a neutral cleaner to wipe off oil or dirt build-up.
2. Storage Bin and Scoop
• Wash your hands before removing ice. Use the plastic scoop provided. (Accessory).
• The storage bin is for ice use only. Do not store anything else in the bin.
• Keep the scoop clean. Clean it by using a neutral cleaner and rinsing thoroughly.
• Clean the bin liner by using a neutral cleaner. Rinse thoroughly after cleaning.
3. Air Filters (air-cooled models only)
Plastic mesh air filters remove dirt and dust from the air and keep the condenser from
getting clogged. As the filters get clogged, the icemaker's performance will be reduced.
Check the filters at least twice a month. When clogged, use warm water and a neutral
cleaner to wash the filters.
4. Condenser (air-cooled and remote air-cooled models only)
Check the condenser once a year, and clean if required by using a brush or vacuum
cleaner. More frequent cleaning may be required depending on the location of the
icemaker or condenser unit.
C. Preparing the Icemaker for Long Storage
When shutting off the icemaker for an extended time, drain out all water from
the water tank and remove the ice from the storage bin. The storage bin should
be cleaned and dried. Drain the icemaker using air or carbon dioxide to prevent
damage to the water supply line at sub-freezing temperatures. Shut off the
icemaker until the proper ambient temperature is resumed.
When the icemaker is not used for two or three days, it is sufficient to only move
the control switch to the "OFF" position, unless the icemaker will be at sub-freezing
temperatures.
CAUTION