Table of Contents 1.Features...................... 1 2.Introduction ....................2 3.Specifications ..................... 7 4.Printed circuit board connector wiring diagram ........9 5.Functions and control ................10 5.1 Main functions and control specification ..........10 5.2 Value of thermistor ................... 15 6. System configuration ................23 6.1 System configuration ................
Features 1. Features Intelligent air With twin-blade technology ,the airflow can be adjusted not to blow directly to human ESF filter : Trap harmful dust and remove unpleasant odors effectively DRY function: Make dehumidifying in the room when the unit is working in the "DRY" mode Anti-mold filter: Catches most small particles and remove unpleasant odors effectively Sleep mode: The setting temprature and the indoor noise can be adjusted to a more comfortable level when you set the "sleep mode"during night sleep...
Introduction 2. Introduction 2.1 Safety Cautions Be sure to read the following safety cautions before conducting repair work. The caution items are classified into “Warning” and “Caution”. The “Warning” items are especially important since they can lead to death or serious injury if they are not followed closely. The “Caution” items can also lead to serious accidents under some conditions if they are not followed.
Introduction Warning Do not repair the electrical components with wet hands. Working on the equipment with wet hands can cause an electrical shock. Do not clean the air conditioner by splashing water. Washing the unit with water can cause an electrical shock.
Page 6
Introduction Warning Be sure to use an exclusive power circuit for the equipment, and follow the technical standards related to the electrical equipment, the internal wiring regulations and the instruction manual for installation when conducting electrical work. Insufficient power circuit capacity and improper electrical work can cause an electrical shock or fire. Be sure to use the specified cable to connect between the indoor and outdoor units.
Page 7
Introduction Warning Do not repair the electrical components with wet hands. Working on the equipment with wet hands can cause an electrical shock. Do not clean the air conditioner by splashing water. Washing the unit with water can cause an electrical shock.
Introduction 2.1.4 Using Icons Icons are used to attract the attention of the reader to specific information. The meaning of each icon is described in the table below: 2.1.5 Using Icons List Icon Type of Information Description A “note” provides information that is not indispensable, but may Note: Note nevertheless be valuable to the reader, such as tips and tricks.
Connector Writing Diagram 4. Printed Circuit Board Connector Wiring Diagram 4.1 Indoor unit Connectors Indoor PCB CN26 CN11 connector for power line L 2) connector for DC fan motor 3) connector for step motor CN32 CN48 connector for receiver display 5) connector for Emergency switch 6) connector for CN54...
Functions and Control 5 Functions and control 5.1 main functions and control specifications Including brief introduction to air conditioners of series models and electric control function. 5.1.1 Automatic running 5.1.1.1 Single cold automatic run mode: After entering into this mode, the main control “MCU” determines the corresponding work pattern according to the indoor temperature so as to maintain the preset temperature (the preset temperature is When the indoor temperature is below , outlet air from compressor is off, the automatic wind from fan...
Page 13
Functions and Control Domestic Air Conditioner...
Page 14
Functions and Control Domestic Air Conditioner...
Page 15
Function and Control Domestic Air Conditioner...
Page 16
Functions and Control 5.1.6 Timer function: You can set 24-hour timer on or timer off as required, and the minum time unit is 1 minute. After setting, the indicator of indoor unit is on , and it is off when timer setting is completed. There are several timer mode as follows.
Functions and Control 5.1.8.4 Enter emergency operation from timer mode, then timer is cancelled. 5.1.9 Test run: 5.1.9.1 The temperature sensor of inlet air doesn’t work, and compressor starts (but subject to the limit of -minute delay excluding the first time), and high wind, cooling, and air door is open.The indoor fan motor runs, running indicator lights up, compressor relay and the one of outdoor fan motor is closed 5.1.9.2 During test run: The prevention of freezing of evaporator doesn’t work.
System Configuration 6. System Configuration 6.1 System Configuration After the installation and test operation of the room air conditioner have been completed, it should be operated and handled as described below. Every user would like to know the correct method of operation of the room air conditioner, to check if it is capable of cooling (or heating) well, and to know a clever method of using it.In order to meet this expectation of the users, giving sufficient explanations taking enough time can be said to reduce about 80% of the requests for servicing.
System Configuration 6.2Parts and Functions Remote controller 9. QUIET button Indoor Unit 10. HEAT button 11. COOL button 12. AUTO button 13. FAN button 14. TIMER button 15. HEALTH button 16. LOCK button Used to lock buttons and LCD display. 17.
System Configuration Operation Emergency operation and test operation Base Operation Emergency Operation: Use this operation only when the remote controller is defective or lost, and with function of emergency running, air conditoner can run automatically for a while. When the emergency operation switch is pressed, the unit Remote controller beeps once, which means the start of this operation.
System Configuration Operation Sleep Operation 3. In AUTO mode Press button to enter additional options, cycle If the unit is running cooling, the sleep mode will follow the display to will flash. And then press the function as in cool mode, while follow as in heat enter for sleep function.
System Configuration Operation Timer On/Off On-Off Operation Healthy airflow Operation 1.After unit starts, select your desired operation mode. 1.Press to starting Setting for comfortable conditions. 2.Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: 2.The setting of healthy airflow function Remote controller: Press...
System Configuration Maintenance For Smart Use of The Air Conditioner Remote Controller Indoor Body Setting of proper room Do not block the air inlet temperature or outlet Proper wipe the air conditioner by using a temperature soft and dry cloth.For serious stains, use a neutral detergent diluted with Do not usewater,wipe the controller water.Wring the water out of the...
Page 31
System Configuration Cautions WARNING This system should be installed by a qualified HVAC professional. Do not attempt to install the air conditioner by yourself improper installation may cause fire, water leakage, personal injury or death. WARNING Check proper Use an exclusive If something abnormal occurs immediately stop the operation button and contact service installation of the...
System Configuration Cautions Trouble shooting Before asking for service, check the following Do not obstruct or cover the ventilation grille of the air first. or any other things into the conditoner.Do not put fingers inlet/outlet and swing louver. Phenomenon Cause or check points Do not allow children to play with the air conditioner .In no When unit is stopped, it won't restart...
Functions and control 7.Codes and Description 7.1.Problem Symptoms and Measures Symptom Check Item Details of Measure Check to make sure that the rated voltage is None of the units Check the power supply. supplied. operates Check the indoor PCB Check to make sure that the indoor PCB is broken Equipment operates but does Diagnosis...
Codes and description 7.2 Error Codes and Description indoor display Code indication Reference Description Page indoor Room temperature sensor failure Indoor Malfunction u l i Indoor fan motor malfunction The code indication that is listed above is the main fault Troubleshooting Caution Be sure to turn off power switch before connect or disconnect connector, or else parts damage may be occurred.
Page 35
Codes and Description Turn off power supply and rotate fan by hand Does fan rotate Replace fan motor smoothly? Turn power ON and operate fan Turn off power supply and disconnect fan Does it rotate? motor connector, then turn power ON Check output of fan motor connector Replace indoor Is motor power voltage...
Installations 9.Installation Manual of Room Air Conditioner Preparation Selection of Installation Place Necessary Tools for Installation Indoor Unit - Select a plocation that is Torque wrench Hammer Robust not causing vibration, where the body can be supported sufficiently. (17mm,22mm,26mm) Nipper Not affected by heat or steam generated in the vicinity, where inlet and outlet of the Hacksaw Pipe cutter...
Installations 1. Insert the drain hose into the dent of heat insulation materials of indoor unit. Accessory parts 2. Insert the indoor/outdoor electric cable from backside of indoor unit, and pull it out on the front side, then connect them. Drain hose (1) 3.
Installations Ensure that on dirt or debris enters the pipe. The standard pipe length is 7m(27 9/16) . If it is over 7m(27 9/16), the function of the unit will be affected. If the pipe has to be lengthened, the refrigerant should be charged, according to 50 g/m(0.045 oz/inch).But the charge of refrigerant must be conducted by professional air conditioner servicer.
Page 44
Installations No gas leakage? On Drainage In case of gas leakage, tighten parts of pipe connection. If leakage stops, then proceed step 6. If leak continues, remove the refrigerant used for the Please install the drain hose so as to be downward slope without fail. leakage check and flare tubes again.
Dimensional drawings 10.4 Dimensional drawings Indoor unit HSU18VHK-G 41.18 in 11.77 in 9.33 in 2.95 in 2.95 in 12.99 in Outdoor unit HSU18VHK-W 33.86 in 32.28 in 12.13 in 0.25 0.37 in(3/8 ) 2.91 in 2.69 in 2.15 in Domestic air conditioner...
Page 50
Center of gravity 10.5 Center of gravity Indoor unit HSU18VHK-G 3.30 in 7.48 in 1.60 in 3.50 in Outdoor Unit HSU18VHK-W 33.86 in 13.78 in Domestic air conditioner...
Page 51
Appendix 10.6 Accessories HSU18VHK-G&W R-03 dry battery Steel nail Plastic cap Cover Cushion Pipe supporting plate Drain-elbow Domestic air conditioner...
Page 52
Applicable voltage:V(208~230V) Nominal cooling capacity (18000BTU/h) The structure code of indoor & outdoor unit: S(wall-mounted) H-Abbreviation of Haier Examples: HSU18VHK,It represents wall-mounted split type heat pump air conditione r.The cooling capacity is 18000BTU/h,and the power supply is 208-230V/60HZ,“K” means the indoor unit series number.
Page 53
The end Sincere Forever Haier Group Edited by:Wang Yujie Haier Industrial Park,NO.1,Haier Road Wang Yueliang 26601,Qingdao,China Signed by:He Shiquan E-mail:hractech@haier.com Approved by:Wu Hongjin Tel:+86 0532 8893 6935 Http://www.haier.com Domestic air conditioner...