Installation Manual of Room Air Conditioner

Preparation
Necessary Tools for Installation
Hammer
Nipper
Hacksaw
Hole core drill
Spanner(17,19 and 26mm)
Gas leakage detector or
soap-and-water solution
Power Source
Before inserting power plug into receptacle, check the voltage without fail.
The power source is the same as the corresponding name plate.
Install an exclusive branch circuit of the power.
A receptacle shall be set up in a distance where the power cable can be
reached.Do not extend the cable by cutting it.
Drawing for the installation of indoor and outdoor units
The models adopt HC FC free refrigerant R410A
more than 5cm
more than
10cm
Arrangement of piping
directions
Rear left
Rear
Left
right
Right
Below
more than 10cm
The marks from
to
A
in the figure are the
G
parts numbers.
The distance between
the indoor unit and the
floor should be more
than 2m.
more than 60cm
The above picture is for your reference only. Your product may look different.
Read this manual before installation.
Explain the operation or the unit to the user according to this manual.
NO.0010532902
Torque wrench
(17mm,22mm,26mm)
Pipe cutter
Flaring tool
Knife
Measuring tape
Reamer
Attention must be paid to
the rising up of drain hose
more than 10cm
more than
10cm
Selection of Installation Place
Indoor Unit - Select a plocation that is
Robust not causing vibration, where the body can be supported sufficiently.
Not affected by heat or steam generated in the vicinity, where inlet and outlet of the
unit are not disturbed.
Possible to drain easily, where piping can be connected with the outdoor unit.
Where cold air can be spread in a room evenly.
Nearby a power receptacle. (Refer to drawings).
Place where the distance of more than lm from televisions, radios, wireless apparatuses
and fluorescent lamps can be left.
In the case of fixing the remote controller on a wall, place where the indoor unit can
receive signals when the fluorescent lamps in the room are lightened.
Outdoor Unit - Select a plocation that is
Not less affected by rain or direct sunlight and is sufficiently ventilated.
Strong enough to bear the unit, where vibration and noise are not increased.
Place, where discharged wind and noise do not cause a nuisance to the neighbors.
Place, where a distance marked
G
F
Floor fixing dimensions of the
A
outdoor unit (Unit:mm)
C
Fixing of outdoor unit
D
E
more than15cm
is available as illustrated in the above figure.
Optional parts for piping
Non-adhesive tape
A
Adhesive tape
B
Saddle (L.S) with screws
C
Connecting electric cable
D
for indoor and outdoor
E
Drain hose
F
Heating insulating material
Piping hole cover
G
Fix the unit to concrete or block
with bolts (10mm) and nuts firmly
and horizontally.
When fitting the unit to wall
surface, roof or rooftop, fix
a supporter securely with nails
or wires in consideration of
earthquake and strong wind.
If vibration may affect the
house, fix the unit by attaching a
vibration-proof mat.

Advertisement

Table of Contents
loading

Summary of Contents for Haier HSU12VHJ

  • Page 1: Installation Manual Of Room Air Conditioner

    fluorescent lamps can be left. Power Source In the case of fixing the remote controller on a wall, place where the indoor unit can receive signals when the fluorescent lamps in the room are lightened. Before inserting power plug into receptacle, check the voltage without fail.
  • Page 2: Indoor Unit

    When connecting the cable before installing the indoor unit Ø70mm Insert the cord from the back side of the unit, then pull it out on the front side. Fasten the unit wire harness to the conduit holder using the lock nut.
  • Page 3: Outdoor Unit

    Ensure that on dirt or debris enters the pipe. Outdoor unit The standard pipe length is 5m. If it is over 10m, the function of the unit will be affected. If the pipe has to be lengthened, the refrigerant should be charged, according to 20 g/m.
  • Page 4 The end is imm- It waves. The gap with the There is the bad To prevent the gas leakage, turn the service port’s cap, the valve rod’s cap for 2-way high midway. ersed in water. ground is too small smell from a ditch valve and 3-way’s a little more than the point where the torque increases suddenly.
  • Page 5: Fuente De Alimentación

    Antes de insertar el enchufe de alimentación en la toma, compruebe que el voltaje ● Elija un lugar que permita soportar el peso de la unidad y que no amplifique el ruido no falla. La fuente de alimentación es la que figura en la placa de datos nominales.
  • Page 6: Unidad Interior

    Accesorios calor de la unidad interior. 2. Inserte los cables eléctricos de interior / exterior a través de la parte trasera de la unidad interior y tire de ellos desde la parte delantera. A continuación, conéctelos. 3. Cubra la cara de sellado con aceite refrigerante y conecte los tubos.
  • Page 7: Unidad Exterior

    Asegúrese de que no penetren residuos o suciedad en el tubo. La longitud estándar del tubo es de 5m. Si el tubo tiene más de 10m, se verán afectadas las funciones de la unidad. Si es necesario alargar el tubo, deberá cargarse refrigerante adicional a razón de 20 g/m.
  • Page 8 Demasiado fuera 7. Para evitar fugas de gas, gire el tapón del puerto de mantenimiento y el tapón del vástago de las válvulas de 2 y 3 vías un poco por encima del punto en el que la torsión aumenta súbitamente.
  • Page 9 (17 mm, 22 mm, 26 mm) Pince ● Solide sans vibration et offrant un support suffisant. ● N'est pas affecté par de la chaleur ou de la vapeur générées dans les environs et Scie à métaux Coupe-tube doit garantir que l'entrée et la sortie de l'unité ne seront pas gênées.
  • Page 10: Unité Intérieure

    fixation. Déplacez l'unité d'un côté vers l'autre pour vérifier la fixation. 1. Exécutez une mise à niveau correcte de la plaque à fixer contre le mur en fonction ● Pour fixer le corps sur la plaque de fixation, soutenez le des piliers ou des linteaux autour, puis attachez la plaque temporairement avec un corps du dessous et reposez-le perpendiculairement.
  • Page 11: Unité Extérieure

    Gaz 15,88mm (5/8") 60 N.m 4. En tournant dans le sens antihoraire, ouvrez le robinet de la vanne à 2 voies à un angle de 90 degrés. Environ 6 secondes plus tard, fermez la vanne à 2 voies et ins-...
  • Page 12 Moins de 7. Pour empêcher toute fuite de gaz, tournez le capuchon de l'orifice d'entretien, le capuchon du robinet des vannes à 2 et 3 voies un peu au-delà du point où le couple Il est surélevé L'extrémité est im-...

This manual is also suitable for:

Hsu18vhj

Table of Contents