Log Placement; Fiber Chunks Placement; Millivolt Appliance Checkout - Lennox Hearth Products EBSTNM-2 Homeowner's Care And Operation Instructions Manual

B-vent multi-open elite series
Table of Contents

Advertisement

Log Placement

WARNING: LOG SET GETS VERY HOT
AND WILL REMAIN HOT UP TO ONE
HOUR AFTER GAS SUPPLY IS TURNED
OFF. HANDLE ONLY WHEN LOG SET IS
COOL. TURN OFF ALL GAS TO THE
APPLIANCE BEFORE INSTALLING THE
GRATE AND LOG SET.
WARNING: THIS APPLIANCE IS NOT DE-
SIGNED TO BURN WOOD. ANY ATTEMPT
TO DO SO COULD CAUSE IRREPARABLE
DAMAGE TO YOUR APPLIANCE AND
PROVE HAZARDOUS TO YOUR SAFETY.
WARNING: THE SIZE AND POSITION OF
THE LOG SET WAS ENGINEERED TO GIVE
YOUR APPLIANCE A SAFE, RELIABLE
AND ATTRACTIVE FLAME PATTERN. ANY
ATTEMPT TO USE A DIFFERENT LOG SET
IN THE FIREPLACE WILL VOID THE WAR-
RANTY AND WILL RESULT IN INCOM-
PLETE COMBUSTION, SOOTING, AND
POOR FLAME QUALITY.
The log set, with one bag of vermiculite, is
packaged in a carton located within the firebox
area. One plastic bag of glowing embers and
one plastic bag of decorative volcanic stone is
located in the bottom compartment. Refer to
the following information and Figures 8 and 9
for detailed placement instructions for the
logs, vermiculite, glowing embers (rockwool)
and decorative volcanic stone. Figure 8 also
shows a typical flame pattern for this particu-
lar appliance.
Install the unitized log set:
a - The bottom of the log set is notched to
accommodate the pilot.
b - Place the log set so that the four inner
notches on the underside of the log set
fit over the four risers located on the burner
ends. See Figure 9 . This procedure is accom-
plished primarily by feel, as the log set masks
the burner risers as it is being installed.
c - As a final check for correct log set place-
ment, check that the four outer notches on the
underside of the log set fit over the burner
tines as indicated in figure 6.
Glowing Embers (Rockwool)
Figure 8
Outer Log
REAR BURNER
Notch Location
Riser - Inner Log
Notch Location
Outer Log
Notch Location
FRONT BURNER
FIREBOX SUBFLOOR
FRONT OF FIREPLACE
LOG NOTCH LOCATION RELATIVE TO BURNER
Figure 9
BURNER POSITIONING
NOTE: INSTALL REAR BURNER FIRST,
THEN FRONT BURNER.
BRACKET A
REAR BURNER
FRONT BURNER
Note: The burners are not identical. Position them so
that the circular burner ports run as shown. Note
especially the vertical run of ports relative to the pilot
burner. Bracket A on the rear burner will interfere
with the pilot burner if an attempt is made to install
the rear burner in the front burner's position.
Figure 10
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Vermiculite
Decorative Volcanic Stone
Note: If the burners have been removed for any
reason, reinstall them as shown in Figure 10.
Outer
Log Notch
Location
Install the vermiculite, decorative volcanic
stone and glowing embers (rockwool):
Riser - Inner Log
Spread vermiculite on the simulated brick floor
Notch Location
of the firebox around the burners to simulate
ashes. Maintain a
Outer Log
Notch Location
tom of the horizontal grate section and the top
of the pile of vermiculite. Sprinkle the decora-
Pilot Assembly
tive volcanic stone on the vermiculite as shown
in Figure 8.
Place a few dime-sized pieces of rockwool on
the pan burner in front of the burned out area
on both sides of the log set. The pieces of
rookwool may touch one another, but should
not overlap each other.

Millivolt Appliance Checkout

The pilot flame should be steady, not lifting or
floating. Flame should be blue in color with
traces of orange at the outer edge.
BURNER
PORTS
The top
(thermopile) and the top
quick drop out thermocouple should be en-
gulfed in the pilot flame. The flame should
project 1" (25 mm) beyond the hood at all three
PILOT
ports. See Figure 11.
BURNER
To light the burner, refer to the lighting in-
structions on pages 14 and 15.
in. gap between the bot-
" (10 mm) at the pilot generator
" min (tip) of the
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents