QAM256 Digital Video Modulator and Upconverter
Opcode: <2009h>
Query response:
<1>
Last Rate Control
Common Command Opcodes
Opcode: <2201h>
<1>
Modem control mode
Opcode: <2204h>
<1>
Hour
<1>
Minute
<1>
Second
Opcode: <2205h>
<1>
Year
<1>
Month
<1>
Day
Opcode: <2206h>
<1>
Year
<1>
Month
<1>
Day
<1>
Hour
<1>
Minute
<1>
Second
Opcode: <2207h>
<0>
Clear Alarms
Opcode: <2208h>
<1>
Common Alarm1
<1>
Common Alarm2
TM077 – Rev. 4.0
(Bit 3 = Spare)
(Bit 4 = Spare)
(Bit 5 = Spare)
(Bit 6 = Spare)
(Bit 7 = Spare)
(0 = mask, 1 = allow)
Query a modulator's Last Rate Control.
(0=Symbol, 1=Data, 2=Auto)
Set Common control mode
(0=Front Panel, 1=Terminal, 2=Computer, 3 = Ethernet)
Set Common time
(0 through 23)
(0 through 59)
(0 through 59)
Set Common date
(0 through 99)
(0 through 11)
(0 through 30)
Set Common time and date
(0 through 99)
(0 through 11)
(0 through 30)
(0 through 23)
(0 through 59)
(0 through 59)
Clear Common Alarms.
(no parameters)
Command Mask Alarms.
(Bit 0 = M&C Hardware Fault)
(Bit 1 = Interface. Hardware Fault)
(Bit 2 = Spare)
(Bit 3 = Spare)
(Bit 4 = Spare)
(Bit 5 = Spare)
(Bit 6 = Spare)
(Bit 7 = Spare)
(0 = mask, 1 = allow)
(Bit 0 = Spare)
(Bit 1 = Spare)
(Bit 2 = Spare)
(Bit 3 = Spare)
(Bit 4 = Spare)
(Bit 5 = Spare)
(Bit 6 = Spare)
(Bit 7 = Spare)
(0 = mask, 1 = allow)
Remote Operations
C-
13