DECOMPRESSION MODEL The programs within the OCS simulate the absorption of nitrogen into the body by using a mathematical model. This model is merely a way to apply a limited set of data to a large range of experiences. The OCS dive computer model is based upon the latest research and experiments in decompression theory. Still, using the OCS, just as using the U.S. Navy (or other) No Decompression Tables, is no guarantee of avoiding decompression sickness, i.e.
INITIAL ACTIVATION OCS Watch/Dive Computers are placed in a Deep Sleep mode prior to being shipped from the factory. The intent is to extend storage life of the Battery for up to 7 years, before the unit is initially placed in service.
• User Upgradeable Firmware. INTERACTIVE CONTROL CONSOLE The Interactive Control Console utilizes 4 control buttons that allow you to maneuver through the OCS's unique system of menus. The buttons will be referred to as M, S, L, and A. • Upper/Left - Mode (M) button.
• On the Surface for 5 minutes after a Conditional Violation. PC INTERFACE Interface with a PC, to allow uploading settings and downloading data, is accomplished by connecting the OCS to a PC USB Port using the special OCS USB Interface Cable.
OCS OPERATING MANUAL POWER SUPPLY • Battery >> (1) 3 vdc, CR2450, Lithium battery. • Shelf life >> up to 7 years (when shipped from factory in Deep Sleep mode). • Use life >> 1 year or 300 dive hours if (2) 1 hour dives per dive day.
OCS OPERATING MANUAL WATCH MAIN (DEFAULT) TIME Main (Default) Time is the Time that is displayed on the Watch until changed. It is also the Time viewed during operation in DC (Dive Computer) Modes. Main Time is the current Time at your home location and is normally selected as the Watch Default Time.
OCS OPERATING MANUAL Set CDT, information includes (Fig. 11): > Graphics SEt and CD TMR. > CDT (hr:min) with Hour digits flashing. > Time (clock) icon. • A (hold) to scroll upward through Hour Set Points at a rate of 8 per second from 0: to 23: in increments of 1: (hr).
OCS OPERATING MANUAL SET TIME MENU • S (< 2 sec) - to access Set Time Menu, while the selection Arrow icon ( > ) is next to Set Time on the Watch Menu. • A (< 2 sec) - to step down (forward) through selections.
Page 15
OCS OPERATING MANUAL • M (< 2 sec) - to step back through Set Points one at a time • S (< 2 sec) - to save the Year Set Point and flash the Month digits • A (hold) - to scroll upward through Month Set Points at a rate of 8 per second from 1 to 12 in increments of 1 •...
OCS OPERATING MANUAL NORM SURF MAIN, information includes (Fig. 24/25): > Graphic NORM. > Graphic SURF and SI (hr:min) with Time (clock) icon; if no dive yet, this is time since access to NORM. > Graphic DIVE and number of dives completed during that operating period, up to 24 (0 if no dive made yet).
OCS OPERATING MANUAL Fly/Desat, information includes (Fig. 29/30): > Time to Fly (hr:min), 0:00 if no dive yet, dashes ( - - : - - ) during first 10 min on surface, with graphic FLY. > Time to Desat (hr:min), 0:00 if no dive yet, dashes ( - - : - - ) during first 10 min on surface, with graphic DESAT.
OCS OPERATING MANUAL Log Data 1, information includes (Fig. 34): > Log Mode (book) icon. > Max Depth with MAX and FT (or M) icons. > Graphic DSAT (or Z+), the Algorithm selected. > Graphic EDT with Dive Time (hr:min).
OCS OPERATING MANUAL • A (< 2 sec) - to step upward through FO2 Set Points. • M (< 2 sec) - to step back through FO2 Set Points. • S (< 2 sec) - save the FO2 setting and flash the PO2 digits (Fig. 38, page 20), or revert to SURF MAIN if Air.
OCS OPERATING MANUAL • A (hold) - to scroll upward through Set Points at a rate of 8 per sec from 0:10 to 3:00 (hr:min) in increments of 0:05 (:min). Set.U • A (< 2 sec) - to step upward through Set Points one at a time.
> Graphic SN (= Serial Number). > OCS's factory programmed SN. > Graphic r1A (or higher), indicating the revision level of the Firmware (OCS's operating software); followed by 01 (or higher), indicating the revision level of the Display. • S (< 2 sec) - to revert to the GAUG Menu if in GAUG mode; or to access Clear (reset) if NORM, refer to page 54 .
24 hour period. The OCS will store O2 calculations for up to 10 dives conducted during a 24 hour period. If the limit for O2 is reached (100% = 300 OTU), all 5 segments of the O2BG will be displayed on the Main dive screen in place of the TLBG (Fig. 60a).
You can select DSAT or Z+. The selection will lock in for 24 hours after the last dive. DSAT has been the standard used by Oceanic in all of its dive computers until this time. It features NDLs that are based on exposures and test data which also formed validation for the PADI RDP.
ERROR (RESET DURING A DIVE) If for any reason, the OCS shuts Off then turns On again during any Dive, the graphic ERR (Error) will be displayed with the Up Arrow icon and current Depth with FT (or M) icon (Fig. 65).
OCS OPERATING MANUAL NO DECO MAIN, information includes (Fig. 67) - > Current Depth with FT (or M) icon, * or dashes during the first 10 minutes on the surface. > DTR (hr:min) with graphic NDC (or OTR), whichever is less at the time, * or dashes during the first 10 minutes on the surface .
OCS OPERATING MANUAL SAFETY STOP MAIN (if Stop Depth/Time set On), information includes (Fig. 74) - > Current Depth with FT (or M) icon. > Stop Depth with FT (or M) and remaining countdown Time (min:sec). > Graphics SAFETY STOP and GAS1 (or 2 or 3), one in use.
OCS OPERATING MANUAL DECO STOP MAIN, information includes (Fig. 79) - > Full Stop icon (Stop Bar with both Arrows) solid. > Current Depth with FT (or M) icon. > Stop Depth with graphic FT (or M) and remaining Stop Time (hr:min).
Page 32
If a Deco Stop Depth greater than 70 FT (21 M) is required, operation will enter VGM. This would be preceded by DV2. Operation would then continue in VGM during the remainder of that dive and for 24 hours after surfacing. VGM turns the OCS into a digital instrument without any decompression or oxygen related calculations or displays.
OCS OPERATING MANUAL VGM Alt 1, information includes (Fig. 90) - > Max Depth with FT (or M) and MAX icons. > Graphic EDT with Elapsed Dive Time (hr:min). • A (< 2 sec) - to access ALT 2. • Revert to Main in 5 sec, if A not pressed.
OCS OPERATING MANUAL PO2 Alarm Alt 2, information includes (Fig. 95) - > Time of Day (hr:min sec), with A (or P) if 12 Hour. > Temperature with ° icon and graphic F (or C). • 5 sec or A (< 2 sec), revert to Main.
Page 35
Oceanic advises that you should not use an OCS. If you exceed certain limits, the OCS will not be able to help you get safely back to the surface. These situations exceed tested limits and can result in loss of some functions for 24 hours after the dive in which a violation occurred.
Page 37
OCS OPERATING MANUAL OVERVIEW > Can only switch when Dive Main screens are displayed. > Cannot Switch Gas on surface. > Cannot Switch Gas during alarms. > All NORM dives begin with Gas 1. > NORM mode defaults to Gas 1 after 10 minutes on the surface.
Page 38
OCS OPERATING MANUAL DIGITAL GAUG MODE STRUCTURE SURFACE Watch. Compass Mode 2 sec 2 sec GAUG. SURF. MAIN ALTs Light < 2 sec closure M or S < 2 sec 2 sec Menu access > selection < 2 sec SET.A <...
OCS OPERATING MANUAL GAUG SURF MAIN, information includes (Fig. 104): > Graphic GAUG. > Graphic SURF and SI (hr:min) with Time (clock) icon; if no dive yet, this is time since access to GAUG. > Graphic DIVE and number of dives completed during that operating period, up to 24 (0 if no dive made yet).
OCS OPERATING MANUAL Upon descent to 5 FT (1.5 M) for 5 seconds, operation will enter GAUG Dive Mode. GAUG DIVE MAIN, information includes (Fig. 110) - > Current Depth with FT (or M) icon. > Run Time (hr:min:sec) with graphic TMR (= Timer), 0:00:00 until started, up to 9:59:59; blank if set OFF.
OCS OPERATING MANUAL FREE DIVE MODE STRUCTURE SURFACE DIVE Surface.Mode 2 sec 2 sec Watch.Mode Compass FREE. 2 FT (0.6 M) for 1 sec SURF. MAIN 5 FT (1.5 M) < 2 sec press for 5 sec .ALTs Light Dive.Mode M or S <...
OCS OPERATING MANUAL FREE MENU M (< 2 sec) - to access Menu, while viewing Surface Main. A (< 2 sec) - to step down (forward) through selections. M (< 2 sec) - to step up (backward) through selections. S (< 2 sec) - to access selection indicated by Arrow icon ( > ).
OCS OPERATING MANUAL Set DD2 Alarm**, information includes (Fig. 132A): > Depth value with FT (or M) and MAX icons. > Graphics DD2 AL. > Graphic OFF (or ON) flashing. • A (< 2 sec) - to toggle OFF/ON • S (< 2 sec) - to save Set Point and flash Depth digits (if ON); or revert to FREE Menu (if OFF), bypassing DD3 ** If this screen is accessed when DD1 is set Off, a message (Fig.
OCS OPERATING MANUAL FREE DIVE MAIN, information includes (Fig. 135) - > Current Depth with FT (or M) icon. > No Deco Time Remaining (hr:min) with graphic NDC. > Elapsed Dive Time (min:sec) with graphic EDT. > TLBG with NI icon, if any from FREE or NORM dives within last 24 hours.
Page 47
The mathematical models currently used in the OCS are based on no decompression/decompression multilevel repetitive dive schedules.
OCS OPERATING MANUAL COMPASS ICONS Diver’s Direction of Turn Left Travel Turn Right North OP Mode Tilt Heading Reference Degrees OP Mode dynamic North or Ref Heading set COMPASS MODE SURFACE REF.Menu rotate (level) Set Ref Surface 2 sec Lock COMP >...
OCS OPERATING MANUAL OVERVIEW > S (2 sec) - to access Compass OP Main from Watch, Surface, or Dive Main. > S (2 sec) or no button action (2 min*) - to revert to Watch, Surface, or Dive Main. *During the final 15 seconds, the remaining On time is displayed. If a button is pressed during that time, the 2 minute On time will reset allowing operation to remain in Compass Mode.
OCS OPERATING MANUAL Set Reference Heading, information includes (Fig. 151) - > Current Depth with FT (or M) icon, blank on surface. > Reference Mode icon (2 bars with arrow) with graphic SET (flashing) above it. > Static Arrow icon (at 12 o'clock), diver direction of travel.
Fig. 159 - ASCENT ALARM Fig. 160 - DEPTH ALARM WARNING: You must become thoroughly familiar with setup and operation of the OCS Digital Compass before using it as your primary device for navigation. Failure to do so could result in serious errors relating to activities involving navigation.
CAUTION: When the procedure provided in this section is used to change the Battery, you must be sure that the case o-ring is not pinched and that the OCS is water tight before conducting diving activities. Pre dive pressure testing by an Authorized Oceanic facility is highly recommended.
A USB Driver is provided on the Oceanlog CD as part of the Interface System. The OCS is configured with a Data Port located on the side (Fig. 161a) that enables it to be connected to a PC USB port using the special Interface Cable.
Instrument Lens Protector. Small scratches will naturally disappear underwater. • Soak and rinse the OCS in fresh water at the end of each day of diving, and check to ensure that the areas around the Low Pressure (Depth) Sensor (Fig. 164a), PC Interface Data Port (Fig. 164b), and Buttons are free of debris or obstructions.
> No adjustments are made during any time that the Wet Contacts are bridged. When diving in high altitude waters from 3,001 to 14,000 feet (916 to 4,270 meters), the OCS automatically adjusts to these conditions providing corrected Depth, and reduced No Deco and O2 Times at intervals of 1,000 feet (305 meters).
OCS OPERATING MANUAL SPECIFICATIONS CAN BE USED AS • Watch • Dive Computer (Air or Nitrox) • Digital Depth Gauge/Timer • Free Dive activity • Compass DIVE COMPUTER PERFORMANCE • Buhlmann ZHL-16c based PZ+, or DSAT based, algorithm • No Deco limits closely follow PADI RDP •...
Page 60
1 second WARNING: If your OCS stops working for any reason while operating as a Dive Computer, it is important that you have anticipated this possibility and are prepared for it. This is an important reason for not pushing the no decompression and oxygen exposure limits, and a critical reason to avoid entering decompression.
OCS Serial Number: ___________________________________________________________________________________________________ OCS Firmware Rev: ___________________________________________________________________________________________________ Date of Purchase: ___________________________________________________________________________________________________ Purchased from: ___________________________________________________________________________________________________ Below to be filled in by an Authorized Oceanic Dealer: Date Service Performed Dealer/Technician OCEANIC WORLD WIDE OCEANIC USA 2002 Davis Street San Leandro, CA 94577...