Summary of Contents for Oceanic OCL

  • Page 1 OCL OPERATING MANUAL WATCH DIVE COMPUTER OPERATING MANUAL © 2002 Design, 2014 Doc. No. 12-5378-r01 (4/9/15)
  • Page 2: Table Of Contents

    OCL OPERATING MANUAL CONTENTS NOTICES ....................3 DIVE MODE FEATURES ..............24 BAR GRAPHS ................25 FEATURES/FUNCTIONS AND WATCH MODE ........5 TLBG (NORM/FREE) ..............25 DISPLAY ICONS ................6 VARI (NORM/GAUG) ..............25 ABBREVIATIONS/TERMS ...............6 ALGORITHM ...................25 CONSERVATIVE FACTOR (CF) .............25 OVERVIEW ..................7 DEEP STOP (DS) ................25 MENU SYSTEM ................7...
  • Page 3: Notices

    The programs within the OCL simulate the absorption of nitrogen into the body by using a mathematical model. This model is merely a way to apply a limited set of data to a large range of experiences. The OCL dive computer model is based upon the latest research and experiments in decompression theory.
  • Page 4 OCL OPERATING MANUAL Welcome OCEANIC THANK YOU for choosing the © 2002 Design, 2014 Doc. No. 12-5378-r01 (4/9/15)
  • Page 5: Features/Functions And Watch Mode

    OCL OPERATING MANUAL FEATURES/FUNCTIONS WATCH MODE © 2002 Design, 2014 Doc. No. 12-5378-r01 (4/9/15)
  • Page 6: Display Icons

    OCL OPERATING MANUAL DISPLAY ICONS Dual Time On Log Mode Surface Interval Daily AL On Depth id Time id Deep Stop is triggered value is PO2 (ATA) Time or # value is Max Depth value is FO2 Low Batt Gas #...
  • Page 7: Overview

    • No Deco Safety Stop INTERACTIVE CONTROL CONSOLE The Interactive Control Console utilizes 4 control buttons that allow you to maneuver through the OCL's unique system of menus. The buttons will be referred to as M, S, A, and L.
  • Page 8: Audible Alarm

    • Upon Surfacing during a Conditional Violation. PC/MAC INTERFACE Interface with a PC or Mac, to allow uploading settings and downloading data, is accomplished by connecting the OCL to a PC or Mac USB Port using the special Oceanic USB Interface Cable.
  • Page 9: Power Supply

    OCL OPERATING MANUAL POWER SUPPLY • Battery >> (1) 3 vdc, CR2032, Lithium battery. • Shelf life >> up to 7 years (when shipped from factory in Deep Sleep mode). • Use life >> 1 year or 300 dive hours if (2) 1 hour dives per dive day.
  • Page 10: Watch Menu

    OCL OPERATING MANUAL WATCH MENU A (< 2 sec) - to step forward through selections one at a time. WATCH MENU S (< 2 sec) - to access the selection displayed. M (< 2 sec) - to step back through selections one at a time.
  • Page 11: Chronograph

    OCL OPERATING MANUAL CHRONOGRAPH The Chronograph is a stop watch timer for use in Watch mode. While the Chronograph is running, it remains on the screen until another screen is accessed, it will then continue to run in the background while on the surface.
  • Page 12: Set T Menu (Time)

    OCL OPERATING MANUAL Each day, at the Time of Day set, the Audible Alarm will sound (if operating in Watch Mode) during which time the hour:minute digits will flash on the Watch Main Time screen (Fig. 15). SET T MENU (TIME) Sequence >>...
  • Page 13: Select Main Time

    OCL OPERATING MANUAL • A (< 2 sec) - to step upward through Day Set Points one at a time. • M (< 2 sec) - to step back through Day Set Points one at a time. • S (< 2 sec) - to save the Date setting and access Set Away Time.
  • Page 14: Dive Computer Operating Modes

    OCL OPERATING MANUAL DIVE COMPUTER OPERATING MODES NORM Mode >> for Air and Nitrox SCUBA activity with 1 or 2 Gases. GAUG Mode >> for SCUBA activity. FREE Mode >> for breath hold diving activity with Depth/Time indication and decompression calculations shared with NORM Mode.
  • Page 15: Norm Surface Modes

    OCL OPERATING MANUAL NORM SURFACE MODES © 2002 Design, 2014 Doc. No. 12-5378-r01 (4/9/15)
  • Page 16: Norm Surf Main

    OCL OPERATING MANUAL NORM SURF MAIN, information includes (Fig. 24A): > Surface Interval time (hr:min) with SURF icon; if no dive yet, this is time since activation > Time of Day (hr:min) with AM or PM icon if 12 Hour Format; no icon if 24 Hour Format >...
  • Page 17: Plan Mode (Norm)

    OCL OPERATING MANUAL FLY/SAT, information includes (Fig. 28A, B): > Graphic FLY with Time to Fly (hr:min), - : - - if no dive yet > Graphic SAT with Time to Desat (hr:min), - : - - if no dive yet, 0:00 if no time remaining •...
  • Page 18: Set Gas Menu (Norm)

    OCL OPERATING MANUAL Log sequence >> Lead-in >> Preview >> Data 1 >> Data 2 >> Data 3 Log Lead-in, information includes (Fig. 31): > Log Mode (book) icon > Graphics NOR - GAU • A (< 2 sec) - to access Set G Lead-in.
  • Page 19: Set Gas 1

    OCL OPERATING MANUAL > MODs (Max Operating Depths) will not be displayed on the FO2 set screen. > internally, it will keep track of O2 data for use if FO2 is subsequently set for Nitrox for repetitive dives. When FO2 is set for Nitrox - >...
  • Page 20: Set A Menu (Norm/Gaug Alarms)

    OCL OPERATING MANUAL SET A MENU (NORM/GAUG ALARMS) Sequence >> Lead-in >> Aud >> Depth >> EDT >> TBG (= TLBG)* >> DTR* *Items apply to NORM only. Set Points remain as set until changed. Set A (Alarms) Lead-in, information includes (Fig. 39): >...
  • Page 21: Set U Menu (Utilities)

    OCL OPERATING MANUAL SET U MENU (UTILITIES) Sequence >> Lead-in >> Wet >> Units >> DS* >> SS* >> Algo* >> CF* >> Glo >> SR *Items apply to NORM only. Set Points remain as set until changed. Set U (Utilities) Lead-in, information includes (Fig. 45): >...
  • Page 22: Set Algorithm (Norm)

    OCL OPERATING MANUAL Set Algorithm, information includes (Fig. 51): > Graphics SEt and ALGO > Graphic PZ+ (or DSAT) flashing • A or M (< 2 sec) - to toggle between DSAT and PZ+. • S (< 2 sec) - to save the setting and access Set Conservative Factor.
  • Page 23: History (Norm/Gaug)

    Fig. 58 - HISTORY 2 SERIAL NUMBER (SN) Information displayed on this screen should be recorded and kept with your sales receipt, it will be required in the event that your OCL requires factory service. Serial Number, information includes (Fig. 59): >...
  • Page 24: Dive Mode Features

    OCL OPERATING MANUAL DIVE MODE FEATURES © 2002 Design, 2014 Doc. No. 12-5378-r01 (4/9/15)
  • Page 25: Bar Graphs

    30 + ALGORITHM The OCL is configured with 2 algorithms which allows you to choose which set of NDLs (No Deco Limits) will be used for nitrogen/oxygen calculations and displays relating to Plan and DTR (Dive Time Remaining). You can select to use either the DSAT or the PZ+. After dives, the selection can be changed once Desaturation time de- creases to 0:00 or 24 hours pass without a dive.
  • Page 26: Safety Stop (Ss)

    DIVE TIME REMAINING (DTR) The OCL constantly monitors No Deco status and O2 Accumulation, and will display whichever Time is the least amount available as Dive Time Remaining on the No Deco Dive Main. The Time being displayed will be identified by the NDC or O2 icon.
  • Page 27: Norm Dive Mode

    OCL OPERATING MANUAL NORM DIVE MODE © 2002 Design, 2014 Doc. No. 12-5378-r01 (4/9/15)
  • Page 28: No Deco Main And Alts

    OCL OPERATING MANUAL NO DECO DIVE MAIN, information includes (Fig. 67): > Current Depth with FT (or M) icon > DTR (Dive Time Remaining) with NDC (or O2) and min icons > Max Depth with MAX and FT (or M) icons >...
  • Page 29: Safety Stop (Ss)

    OCL OPERATING MANUAL SAFETY STOP MAIN, information includes (Fig. 73): > Current Depth with FT (or M) icon > DTR (min) with NDC (or O2) and min icons > Stop Depth set with FT (or M) icon > Stop icon (arrows/bar) >...
  • Page 30: Cv (Conditional Violation)

    OCL OPERATING MANUAL Deco Stop Alt 3 (if Nitrox), information includes (Fig. 79) - > % O2 with O2sat icon > Current PO2 value (ATA) with icon > FO2 value set for the Gas in use with icon > Gas 1 (or 2) icon, the one in use •...
  • Page 31: High Po2

    OCL OPERATING MANUAL Upon activation of VGM, the Audible will sound and the alarm LED will flash. The graphic VIO and Up Arrow icon will flash. VGM Dive Main, information includes (Fig. 84) - > Current Depth with FT (or M) icon >...
  • Page 32: High O2

    OCL OPERATING MANUAL High PO2 during Deco (Fig. 88) The PO2 alarm settings do not apply when in Deco which has a fixed alarm of 1.60 (ATA). > If PO2 reaches 1.60 while at a Deco Stop, the PO2 value (1.60) with icon will alternate with Deco Stop Depth/Time once each minute*.
  • Page 33 OCL OPERATING MANUAL To Switch Gas, while viewing a NORM Dive Main: • M (2 sec) - to access the Preview screen for the Gas currently in use (Fig. 92). • M (2 sec)* again - to access other Gas' Preview (similar).
  • Page 34: Digital Gauge Mode

    OCL OPERATING MANUAL DIGITAL GAUGE MODE © 2002 Design, 2014 Doc. No. 12-5378-r01 (4/9/15)
  • Page 35: Gaug Surf Main

    OCL OPERATING MANUAL GAUG SURF MAIN, information includes (Fig. 94): > Surface Interval time (hr:min) with SURF icon; if no dive yet, this is time since activation > Time of Day (hr:min) with AM or PM icon if 12 Hour Format; no icon if 24 Hour Format >...
  • Page 36: Gaug Dive Main And Alts

    OCL OPERATING MANUAL Upon descent to 5 FT (1.5 M) for 5 seconds, operation will enter Gauge Dive Mode. GAUG DIVE MAIN, information includes (Fig. 97A, B) - > Current Depth with FT (or M) icon Fig. 97A - GAUG DIVE MAIN >...
  • Page 37: Free Dive Mode

    OCL OPERATING MANUAL FREE DIVE MODE © 2002 Design, 2014 Doc. No. 12-5378-r01 (4/9/15)
  • Page 38: Free Surf Main

    OCL OPERATING MANUAL FREE SURF MAIN, information includes (Fig. 102): > Surface Interval time (min:sec up to 59:59, then hr:min) with SURF icon; if no dive yet, this is time since activation > Time of Day (hr:min) with AM (or PM) icon >...
  • Page 39: Free Set Fa Menu (Free Alarms)

    OCL OPERATING MANUAL >> If On is saved and a CDT was set, the CDT will start counting down and operation will revert to the Lead-in. >> If Off is saved, the Timer will stop counting down and operation will revert to the Lead-in.
  • Page 40: Free Dive Main And Alt

    OCL OPERATING MANUAL SELECT OP MODE The Lead-in screen (Fig. 111) and selecting a Dive Operating Mode are similar to that previously described for NORM. Refer to page 22. SHARED SETTINGS To change items that FREE Mode shares with NORM Mode, first access the NORM Menu, then Set U, then select Set - >...
  • Page 41: Free Dive Alarms

    OCL OPERATING MANUAL FREE DIVE ALARMS FREE mode alarms, which are separate from NORM (or GAUG) alarms, sound either 1 or 3 times as 3 beeps then clear. They cannot be acknowledged or silenced. FREE COUNTDOWN TIMER (CDT) Alarm When a set Countdown Time reaches 0:00, the audible will sound during which time the graphics CDT - 0:00 will flash on the Main in place of Temperature and EDT (Fig.
  • Page 42: Reference

    OCL OPERATING MANUAL REFERENCE © 2002 Design, 2014 Doc. No. 12-5378-r01 (4/9/15)
  • Page 43: Pc Interface, Pc/Mac Requirements

    A USB Driver is provided on the Oceanlog CD as part of the Interface System. The OCL is configured with a data contacts located on the side that enables it to be connected to a PC or Mac USB port using the special Interface Cable.
  • Page 44: Care And Cleaning

    Instrument Lens Protector. Small scratches will naturally disappear underwater. • Soak and rinse the OCL in fresh water at the end of each day of diving, and check to ensure that the areas around the Low Pressure (Depth) Sensor (left side), PC Interface contacts (right side), and Buttons are free of debris or obstructions.
  • Page 45 (Fig. 138a) and the tab (Fig. 138b) lined up with the watch housing. • Carefully position the Battery Cover over the battery compartment. Use the OCL logo as a guide for top/bottom. Also, a small arrow has been engraved on the top of the Cover to serve as a guide. The arrow should be pointing towards the strap with a metal clasp.
  • Page 46: Clear (Reset)

    > No adjustments are made during any time that the Wet Contacts are bridged. > When diving in high altitude waters from 3,001 to 14,000 feet (916 to 4,270 meters), the OCL automatically adjusts to these conditions providing corrected Depth, and reduced No Deco and O2 Times at intervals of 1,000 feet (305 meters).
  • Page 47: Technical Data

    OCL OPERATING MANUAL TECHNICAL DATA © 2002 Design, 2014 Doc. No. 12-5378-r01 (4/9/15)
  • Page 48: Dsat Algorithm Ndl Chart

    OCL OPERATING MANUAL DSAT BASED NDLS (HR:MIN) (IMPERIAL) Altitude 3001 4001 5001 6001 7001 8001 9001 10001 11001 12001 13001 (feet) 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 14000 Depth (FT) 4:20 3:21 3:07 2:55 2:45...
  • Page 49: Pz+ Algorithm Ndl Chart

    OCL OPERATING MANUAL Z+ BASED NDLS (HR:MIN) (IMPERIAL) Altitude 3001 4001 5001 6001 7001 8001 9001 10001 11001 12001 13001 (feet) 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 14000 Depth (FT) 3:17 2:30 2:21 2:14 2:08...
  • Page 50: Specifications

    OCL OPERATING MANUAL SPECIFICATIONS CAN BE USED AS • Watch • Dive Computer (Air or Nitrox) • Digital Depth Gauge/Timer • Free Dive activity DIVE COMPUTER PERFORMANCE • Buhlmann ZHL-16c based PZ+, or DSAT based, algorithm. • No Deco limits closely follow PADI RDP.
  • Page 51 OCL OPERATING MANUAL SPECIFICATIONS (CONTINUED) NUMERIC DISPLAYS: Range: Resolution: • Main Time of Day 00:00:00 to 23:59:59 hr:min:sec 1 second • Dual Time of Day 00:00 to 23:59 hr:min 1 minute • Dual Time Differential OFF, + 01 to + 23, - 23 to - 01 hr 1 hour •...
  • Page 52: Inspection/Service Record

    Serial Number: ___________________________________________________________________________________________________ Firmware Rev: ___________________________________________________________________________________________________ Date of Purchase: ___________________________________________________________________________________________________ Purchased from: ___________________________________________________________________________________________________ Below to be filled in by an Authorized Oceanic Dealer: Date Service Performed Dealer/Technician OCEANIC WORLD WIDE OCEANIC USA 2002 Davis Street San Leandro, CA 94577 Tel: 510/562-0500 Fax: 510/569-5404 Web: www.OceanicWorldwide.com...
  • Page 53 OCL OPERATING MANUAL WATCH DIVE COMPUTER OPERATING MANUAL © 2002 Design, 2014 Doc. No. 12-5378-r01 (4/9/15)