Chapter 4 Parameter Settings|DD Series
10
OD command
11
CD command
12
Demo Indication
Demo complete
13
14
Emergency stop indication
15
Force stop indication
Door open complete (limit)
16
signal output
Door close complete (limit)
signal output
17
Door close error
18
Position complete signal
19
Position Detection 1(for door
20
close only)
Position Detection 2(for door
21
close only)
Position Detection 3(for door
22
close only))
Position Detection 1(for door
23
open only)
Position Detection 2(for door
24
open only)
Position Detection 3(for door
25
open only)
26
PG feedback error
output signal when unable to
27
open the door
over torque (OT1)
28
Digital Output Direction
Control mode
VF
Settings
This parameter is set via bit setting. If a bit is 1, the corresponding output acts in the opposite way.
Example:
If Pr02-08=1 (operation indication) and Pr.02-13=0, Relay 1 RA-RC is closed when the drive runs and is
open when the drive is stopped.
If Pr02-08=1 and Pr02-13=1, Relay 1 RA-RC is open when the drive runs and is closed when the drive is
stopped.
Position Detection Signal 1
Control mode
VF
Settings
Position Detection Signal 2
VFPG
SVC
FOCPG FOCPM
00~65535
VFPG
SVC
FOCPG FOCPM
0.0~100.0%
Active when the operation direction is door open.
Active when the operation direction is door close.
Active when the drive is in demo mode.
Active when each time door open/close is complete in demo
mode (contact closed for 0.5s only).
Active when emergency stop is detected.
Active when force stop is detected.
Active when position mode (Pr.06-11) is set to "no door close
limit signal" and the door width is greater than the setting in
Pr.04-06.
Active when position mode (Pr.06-11) is set to door close limit
signal allow and one of MI (Pr.02-01~02-05) is set to 14.
Active when position mode (Pr.06-11) is set to "no door close
limit signal" and the door width is less than Pr.05-06 setting
during the door close.
Active when position mode (Pr.06-11) is set to door close limit
signal allow and one of MI (Pr.02-01~02-05) is set to 15.
Active when door close error. (Includes door reopen and not
reopen).
Active when positioning is completed after drive power is on or
PGEr. This function is valid when Pr.00-10=00.
Active when door close width is lower than Pr.06-14 (valid when
door close).
Active when door close width is lower than Pr.06-15 (valid when
door close).
Active when door close width is lower than Pr.06-16 (valid when
door close).
Active when door close width is lower than Pr.06-14 (valid when
door open).
Active when door close width is lower than Pr.06-14 (valid when
door open).
Active when door close width is lower than Pr.06-14 (valid when
door open).
Active when PG feedback signal error is detected
4-42
Factory setting: 0
Factory setting: 25.0