Chapter 4 Parameter Settings|DD Series
4-2 Description of Parameter Settings
00 System Parameter
Identity Code of AC Motor Drive
Control mode
VF
Settings
Rated Current Display of AC Motor Drive
Control mode
VF
Settings
Pr. 00-00 displays the identity code of the AC motor drive. The capacity, rated current, rated voltage and
the max. carrier frequency relate to the identity code. Users can use the following table to check how the
rated current, rated voltage and max. carrier frequency of the AC motor drive corresponds to the identity
code.
Pr.00-01 displays the rated current of the AC motor drive. By reading this parameter the user can check if
the AC motor drive is correct.
Parameter Reset
Control mode
VF
Settings
When it is set to 1, all parameters are read only except Pr.00-00~00-07 and it can be used with password
setting for password protection.
When Pr.00-02=10, all parameters are reset to factory setting. If password lock was used, please unlock
first. After Pr.00-02 set to 10, password will also be cleared and reset to factory setting.
When Pr.00-02=08, the digital keypad will be locked and only Pr.00-02, Pr.00-07 can be set.
Start-up Display Selection
Control mode
VF
Settings
This parameter determines the start-up display page after power is applied to the drive.
Content of Multi Function Display
Control mode
VF
Settings
VFPG
SVC
FOCPG FOCPM
0:200w
1:400w
VFPG
SVC
FOCPG FOCPM
0:1.50A
2:2.50A
VFPG
SVC
FOCPG FOCPM
0: No function
1: Parameters locked
8: Keypad locked
10: All parameters are reset to factory setting (33.3Hz, 230V)
VFPG
SVC
FOCPG FOCPM
0: Display the frequency command value (F)
1: Display the actual output frequency (H)
2: Display the content of user-defined unit (U)
3: Display the output current (A)
VFPG
SVC
FOCPG FOCPM
0: Display output current (A )
1: Display actual frequency (Hz)
2: Display DC-BUS voltage ( U)
3: Display output voltage( E )
4: Display power factor angle (n.)
This parameter can be set during operation.
4-24
Factory setting: Read only
Factory setting: Read only
Factory setting: 0
Factory setting: 0
Factory setting: 2