Appendix A Specifications - Delta Electronics VFD-DD Series User Manual

Vfd-dd series door drives and motors
Table of Contents

Advertisement

VDD-DD series provide our customers 230V-200W model and 230V-400W model, choose the
one that fits your need. The table below facilitates our customers' purchase.
Drive Specifications
Model VFD-_ _ _DD
Applicable Motor Output(W)
Rated Output Capacity
(kVA)
Rated Output Current
(A)
Maximum Output
Voltage (V)
Output Frequency (Hz)
Carrier Frequency
(kHz)
Rated Input Current (A)
Voltage Tolerance
Frequency Tolerance
Cooling Method
Frame Size
Common Characteristics
Control Method
Starting Torque
Speed Control Range
Speed Control Accuracy
Speed Response Ability
Max. Output Frequency (Hz)
Output Frequency Accuracy
Frequency Setting
Resolution
Torque Limit
Accel/Decel Time
V/F Curve Pattern
Brake Torque
Keypad
Frequency
Setting
External Signal
Signal
Operation
Keypad
Setting
External Signal
Signal
Multi-Function Input Signal

Appendix A Specifications

002
200
0.6
1.5
Proportional to Input Voltage
4.9A
Single phase 200~ 240V (-20%~+10%) (160~264V)
50/60Hz ±5% (47~63Hz)
200W natural cool /400W natural cool
W170mm*L215*H55mm
1: V/F, 2: VF+PG, 3: SVC, 4: FOC+PG, 6:PM FOC+PG
Starting torque at 0.5Hz is more than 150%, at 0 Hz is FOC+PG
1:100(external PG installation can achieve 1:1000)
±0.5% (external PG installation can achieve ±0.02%)
5Hz (vector control can attain 30Hz)
200% torque current as maximum
Adjustable V/F curve of 4 independent points
50% ED for 3 seconds, during every 30 seconds (optional)
Multi-function input selection 1~5 (15 step speeds; At low speed),
parameter setting on serial communication port (RS-485)
2 wires (OD, CD, RUN), At low speed operation, RS-485 serial
Multi-step speed selection MI1~MI15, At low speed, first to second
accel/decel switches, demo mode, force stop, emergency stop,
operation command source, parameter lock, driver reset,
open/close limit signal, door open prohibited signal, force open
signal, reposition, 2nd step open/close curve selection
A-1
Appendix A Specifications |DD Series
0.00~120.00Hz
10 kHz
control mode
0.00 to 120.00 Hz
Digital command ±0.005%
Digital command ±0.01Hz
0.00~600.00 sec
By parameter setting
Set by RUN, STOP key
interface, demo mode
004
400
1.0
2.5
6.5A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents