SET READY - Range: 185˚F (85˚C) to 203˚F (95˚C)
This function allows the operator to set the minimum temperature allowable to start a brew cycle. The range
can be from 185˚F (85˚C) to within 2˚F (-1.7°C) of the SET TEMP. The water must be at the SET READY tempera-
ture or higher for the display to indicate READY TO BREW. If brew lockout is enabled, the brewing process will
not start below this READY temperature.
NOTE: The upper limit for SET READY temperature is 2˚F (-1.7°C) less than the water temperature (SET TEMP)
setting.
Procedure to set ready temperature:
1. Press and hold upper right hidden switch until the display reads UNITS. Release switch. Press and release
upper right hidden switch until the display reads SET READY.
2. To adjust the ready temperature, press the (-) button to decrease, or (+) to increase the ready temperature.
3. When finished, press and release DONE to save the new setting, exit the SET READY function and advance
to the next function screen, REFILL. Another alternative is to press and release either ON/OFF switch located
on the front switch panel to exit the SET READY function and return to the MAIN SCREEN.
1. Select the desired batch size on the grinder. It is not necessary to select a size on the brewer.
2. Insert a BUNN filter into the funnel.
3. Grind or pour the proper amount of fresh ground coffee into the filter and level the grounds by gently shaking.
4. Slide the funnel into the funnel rails. If the grounds are not obtained through a grinder compatible with a
Smart Funnel, a batch size must be chosen on the brewer.
5. Place an empty server under the funnel.
6. The ENABLE BREW switch must be ON. Momentarily press and release the BREW switch. If the brewer has
the funnel lock option and if it is activated, once a brew cycle has been started the funnel is locked in place.
There may be certain situations in which the brew cycle will not begin when the BREW switch is pressed:
a) BREW TEMPERATURE TOO LOW - wait until heated or cancel BREW LOCKOUT option.
b) FUNNEL NOT IN PLACE (or using a standard brew funnel) - cancel FUNNEL DETECT option.
c) CHECK FUNNEL - remove funnel, empty previously brewed grounds and grind a new batch into the funnel.
7. If none of the above messages are displayed, the display will read NOW BREWING and the time remaining
in the brew cycle.
8. Following the BREW will be a countdown of drip time DRIPPING which shows the time remaining until the
funnel lock will release. Discard the grounds and filter only after visible dripping stops.