Operating the Temperature Control System

Figure 24: Status Codes
Status Light Code
Table 6
LED FLASH SEQUENCE
Short flash once every four second
"Heartbeat", alternates bright/dim
One Flash, three second pause
Two Flash, three second pause
Three Flash, three second pause
Four Flash, three second pause
Five Flash, three second pause
Six-One Flash, three second pause
Six-Two Flash, three second pause
Six-Three Flash, three second pause
Six-Four Flash, three second pause
Seven Flash, three second pause
Eight-One Flash, three second pause
Eight-Two Flash, three second pause
Eight-Three Flash, three second pause
Eight-Four Flash, three second pause
20
Status
Light
STATUS
ON
OFF
LOW
VAC
IDLE (No call for heat, no fault conditions)
Call for Heat (No fault conditions)
Low Flame Signal (control continues to operate)
End Switch Failed Closed
End Switch Failed Open or TCO Limit Lockout
ECO Limit Lockout
Flame Out of Sequence
Soft Lockout - Retry Limit - Failed TFI
Soft Lockout - Recycle Limit - Flame Lost - END Switch Fails
Soft Lockout - Recycle Limit - Flame Lost
Soft Lockout - Flame out of Sequence Sensed
Flammable Vapor Sensor (FVS) Lockout
Flammable Vapor Sensor (FVS) Fault Detected
Temperature Sensor Fault Detected
Electronic Fault Detected
Gas Control Valve/Thermostat Fault Detected

Water Temperature Adjustment

The water temperature can be adjusted from 70°F to 160°F.
Turn the Gas Control/Temperature Knob to the desired
setting/temperature.

Operating Modes and Settings

Standard Mode - The controller adjusts the water
heater to maintain the temperature set by the user.
Vacation Setting - The controller adjusts the water
temperature to approximately 70°F. This setting is
recommended when the water heater is not in use for
a long period of time. This effectively turns the water
heater down to a setting that prevents the water from
freezing.