Section 5: Venting Systems; Direct Connect With Outside Air; Direct Connect Without Outside Air - Quadra-Fire CB1200-I Pellet Insert CB1200I-B Owner's Manual

Installation and operation
Hide thumbs Also See for CB1200-I Pellet Insert CB1200I-B:
Table of Contents

Advertisement

CB1200-I Pellet Insert
5
Venting Systems
A. Direct Connect With Outside Air
Outside Air
through
Rear Wall
Figure 14.1
NOTE:
Illustrations reflect typical installations and are FOR
DESIGN PURPOSES ONLY.
Illustrations/diagrams are not drawn to scale.
Actual installation may vary due to individual design
preference.
CAUTION
Never draw outside combustion air from:
Wall, floor or ceiling cavity
Enclosed space such as an attic or garage
Page 14
NOTE: In Canada, only a full reline is
allowed per ULC S-628, ORD ULC C1482.
NOTE; Use metal plate
around exhaust vent pipe
and seal all edges with
non-flammable insulation
such as fiberglass, mineral
wool or ceramic material.
Do not use high tempera-
ture caulking materials to
seal any edge to prevent
future serviceability.
7014-083E
B. Direct Connect Without Outside Air
Figure 14.2
WARNING
Fire Risk.
Inspection of Chimney:
• Masonry chimney must be in good condition.
• Meets minimum standard of NFPA 211
• Factory-built chimney must be 6 inch (152mm)
UL103 HT.
NOTE:
In Canada, where passage through a wall or partition of
combustible construction is desired, the installation shall
conform to CAN/CSA-B365.
R
September 1, 2008