Maintaining & Servicing Your Appliance
A. General Maintenance
1. Creosote (Chimney) Cleaning
Frequency: Every 2 months during heating season or
as recommended by a certified chimney
sweep; more frequently if chimney exceeds
or is under 14-16 ft. (measured from bottom
of appliance)
By: Certified Chimney Sweep
Remove all ash from the firebox and extinguish all hot
embers before disposal. Allow the appliance to cool
completely. Disconnect flue pipe or remove baffle and
ceramic blanket from appliance before cleaning chimney.
Otherwise residue can pile up on top of the baffle and
ceramic blanket and the appliance will not work properly.
(See Baffle Removal on page 34). Close the door tightly.
The creosote or soot should be removed with a brush
specifically designed for the type of chimney in use. Clean
out fallen ashes from the firebox.
It is also recommended that before each heating season
the entire system be professionally inspected, cleaned and
repaired if necessary.
Inspection: Inspect the system at the appliance connection
and at the chimney top. Cooler surfaces tend to build
creosote deposits quicker, so it is important to check the
chimney from the top as well as from the bottom.
Formation and Need For Removal: When wood is burned
slowly, it produces tar and other organic vapors which
combine with expelled moisture to form creosote. The
creosote vapors condense in the relatively cool chimney
flue of a newly-started or a slow-burning fire. As a result,
creosote residue accumulates on the flue lining. When
ignited, this creosote creates an extremely hot fire which
may damage the chimney or even destroy the house. The
chimney connector and chimney should be inspected once
every 2 months during the heating season to determine if a
creosote or soot buildup has occurred. If creosote or soot
has accumulated, it should be removed to reduce the risk
of a chimney fire.
WARNING
Fire Risk.
Prevent creosote buildup.
• Inspect chimney connector and chimney once
every two months during heating season.
• Remove creosote to reduce risk of chimney fire.
• Ignited creosote is extremely HOT.
September 1, 2008
2100 Millennium Wood Stove (ACC)
Fire Risk.
Do not use chimney cleaners or flame colo-
rants in your appliance.
Will corrode pipe.
2. Disposal of Ashes
Frequency: When ash is within 1-/4 in. (44mm) of
firebox lip
By: Homeowner
Ashes should be placed in a metal container with a
tight fitting lid. The closed container of ashes should
be placed on a non-combustible floor or on the ground,
well away from all combustible materials, pending final
disposal. If the ashes are disposed of by burial in soil
or otherwise locally dispersed, they should be retained
in the closed container until all cinders have thoroughly
Fire Risk.
Disposal of Ashes
• Ashes should be placed in metal container with tight
fitting lid.
• Do not place metal container on combustible
surface.
• Ashes should be retained in closed container until all
cinders have thoroughly cooled.
3. Glass Cleaning
Frequency: As desired
By: Homeowner
Clean glass with a non-abrasive glass cleaner. Abrasive
cleaners may scratch and cause glass to crack. If the
deposits on the glass are not very heavy, normal glass
cleaners work well. Heavier deposits may be removed
by using a damp cloth dipped in wood ashes or by using
a commercially available oven cleaner. After using an
oven cleaner, it is advisable to remove any residue with
a glass cleaner or soap and water. Oven cleaner left on
during the next firing can permanently stain the glass
and damage the finish on plated metal surfaces.
A portion of the combustion air entering the firebox is deflected
down over the inside of the door glass. This air flow "washes"
the glass, helping to keep smoke from adhering to its surface.
When operated at a low burn rate, less air will be flowing
over the glass and the smokey, relatively cool condition of a
low fire will cause the glass to become coated. Operating
the appliance with the Burn Rate Air Control and Start-Up Air
Control all the way open for 15-20 minutes should remove
the built up coating.