R
Thimble
Site constructed for masonry chimney installation:
Components
• A minimum length of 12 inches [05mm] (longer for
thicker walls) of solid insulated factory-built chimney
length constructed to UL 10 Type HT 6 inch (152mm)
inside diameter. Chimney needs to extend a minimum
of 2 inches (51mm) from the interior wall and a mini-
mum of 1 inch (25mm) from the exterior wall.
• Wall spacer, trim collar and wall band to fit solid pack
chimney selected.
• Minimum 8 inch (20mm) diameter clay liner section (if
not already present in chimney) and refractory mortar.
Air Clearances
• Masonry chimney clearance must meet NFPA 211 mini-
mum requirement of 2 inches (51mm) to sheet metal
supports and combustibles.
• Minimum of 1 inch (25mm) clearance around the chim-
ney connector.
• Top of wall opening is a minimum of 1-1/2 inches
(4mm) from ceiling or 4-1/2 inches (114mm) below
minimum clearance specified by chimney connector
manufacturer. NFPA 211 minimum vertical clearance of
18 inches (457mm) from chimney connector and ceil-
ing or minimum recommended by chimney connector
manufacturer. Figure 15.1.
Instructions:
1. Open inside wall at proper height for the chimney con-
nector to entry the masonry chimney. Figure 15.1
2. Entry hole to masonry chimney must be lined with an 8
inch (20mm) minimum diameter clay liner, or equiva-
lent, secured with refractory mortar.
. Construct a 17 inch x 17 inch (42mm x 42mm) out-
side dimension frame from 2 x 2 framing lumber to
fit into wall opening. Inside opening of frame should
be no less than 14 inch x 14 inch (56mm x 56mm).
Figure 15.1.
4. Attach the wall spacer to the chimney side of the
frame.
5. Nail the frame into the wall opening. The spacer should
be on the chimney side.
6. Insert the section of the solid insulated chimney into
the outer wall of the masonry chimney.
7. Tightly secure the length of the solid insulated chimney
with the wall band to the masonry chimney.
8. Insert a section of chimney connector into the chimney.
Make sure it does not protrude past the edge of the
clay chimney liner inside the chimney.
9. Seal the end of the chimney connector to the clay liner
with refractory mortar.
10. Install trim collar around the sold pack chimney section.
September 1, 2008
2100 Millennium Wood Stove (ACC)
Minimum18.0"
NFPA 211
17.0" OD
14.0" ID
8.0"
Center of Hole
Thimble
Include depth
of hearth pad
Figure 15.1
Solid Pack Chimney with Metal Supports as a Thimble
Trim Collar
Chimney Section
with 2 inch
(51mm)
Clearance to
Combustibles
Figure 15.2
Fire Risk.
Do NOT pack insulation or other combustibles between
spacers.
ALWAYS maintain specified clearances around vent-
ing and spacers.
Install spacers as specified.
Failure to keep insulation or other material away from
vent pipe may cause fire.
7039-131F
C L
ceiling
13.5" below ceiling to top
of opening
Wall
or top of opening is a min.of
4.5" below min.clearance
specified by connector mfg.
1.5 2x2 framing stud
2.0 min air clearance
1.0 min air clearance
4.5
1.5"
2.0"
2.0"
1.5"
Fire Clay Flue
with Airspace
Secure Chimney
Chimney
Wood Studs Used
Connector
for Framing - Spaced
2 inch (51mm)
clearance from
Masonry Chimney
WARNING
1.0"
C L
1.0"
Liner
Masonry
Chimney
Wall Spacer
Wall Band to
Section