Finishing; Mantel And Wall Projections; Facing Material - Hearth and Home Technologies TWILIGHT-II-B Owner's Manual

Installation and operation
Table of Contents

Advertisement

10
10

Finishing

A. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances as specifi ed. Framing closer than the minimums list-
ed must be constructed entirely of noncombustible materi-
als (i.e., steel studs, concrete board, etc.) Failure to comply
could cause fi re.
NON-COMBUSTIBLE BOARD
(SUPPLIED ON APPLIANCE)
INDOOR SIDE ONLY
Figure 10.1 Clearances to a Combustible and/or Non-combustible
Indoor Mantel
MEASURED
FROM CORNER
FIREPLACE
HOOD
Figure 10.2 Clearances to a Combustible and/or Non-combustible
Indoor Mantel or Mantel Leg
30
Outdoor Lifestyles by Hearth & Home Technologies, Inc. • Twilight-II-B • 2108-900 Rev. V • 5/11
CEILING
12
11
10
35-3/4
9
8
7
13-5/8
12-5/8
6
11-5/8
10-5/8
9-5/8
8-5/8
7-5/8
HOOD
Note: Measurements are in inches.
TOP VIEW
1/2 IN.
B. Facing Material
Inside Facing Material
• May install combustible materials up to specified
clearances on top, front and sides of appliance.
• Seal joints between fi nished wall and appliance top and
sides with 300ºF (140º C) minimum sealant.
• Leave space so bottom grille can be lowered for trim
door removal.
WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specifi ed in
this manual. Overlapping materials could ignite and will
interfere with proper operation of doors and louvers.
NON-COMBUSTIBLE ZONE
41-7/8 in.
Figure 10.3 Non-combustible Zone (Interior)
Finishing Material Clearances
OVERHANG
FINISHING MATERIALS
A
SIDING
MINIMUM CLEARANCES
Vinyl
A
36 in.
B
64-5/16 in.
Figure 10.4 Exterior View - Finishing Material Clearances
2-3/4 in.
A
SIDING
A
SIDING
Non-vinyl
12 in.
35-5/16 in.
B

Advertisement

Table of Contents
loading

This manual is also suitable for:

Twilightlp-ii-b

Table of Contents