WARNING
Fire Risk
Asphyxiation Risk
Do not draw outside combustion air from:
• Wall, floor or ceiling cavity.
Enclosed space such as an attic or
garage.
Close proximity to exhaust vents or
chimneys.
Fumes or odor may result.
CAUTION
Risk of Smoke Spillage
Outside air inlet must be located to prevent blockage
from:
• Leaves
• Snow/ice
• Other debris
Blockage may cause combustion air starvation.
Attic insulation shield
must be used to keep
insulation away from
chimney.
Ceiling firestop
on floor of attic.
Figure 16.1 Outside Air Inlet Locations
Page 16
Heat & Glo • NorthStar EPA Fireplace • 480-1081C
Handle Left - Closed
Handle Right - Open
Figure 16.2 Locating the Outside Air Control
3 ft. (91cm) min. from top of
uppermost chimney
section to air inlet.
September 1, 2008