DC Negative Cable – Route the appropriately sized cable from the battery negative terminal to
the shunt, and from the other side of the shunt to the inverter's negative DC terminal.
IMPORTANT
The side of the shunt that connects to the inverter should be considered the DC negative bus in
order for the State of Charge (SOC) function to operate properly.
IMPORTANT
Le côté du shunt qui se relie à l'inverseur devrait être considéré l'autobus négatif de C.C afin de
l'état de fonction de la charge (SOC) à fonctionner correctement.
DC Positive Cable - Route the appropriately sized cable from the battery cable terminal to the circuit
breaker.
CAUTION
Observe the proper polarity (line side vs. load side) on DC circuit breakers.
ATTENTION
Observez la polarité appropriée (ligne côté contre le côté de charge) sur des disjoncteurs de
C.C.
WARNING
Assure that the DC circuit breaker is off when connecting the positive battery cable to avoid
activating the inverter prematurely.
AVERTISSEMENT
Assurez que le disjoncteur de C.C est outre de en reliant le câble positif de batterie pour éviter de
déclencher l'inverseur prématurément.
Next route the appropriately sized cable from the other side of the circuit breaker to the positive DC
terminal on the inverter.