Front Installation - Quadra-Fire Direct Vent Room Heater 839-1390 Owner's Manual

Direct vent room heater
Table of Contents

Advertisement

E. Front Installation
Fronts are shipped attached to the face.
INSTALLATION AND REMOVAL INSTRUCTIONS FOR
QUARTET AND SOLITAIRE FACE OPTIONS.
Quartet Front
Figure 8.12
For BOTH Quartet and Solitaire Fronts:
To remove the face, loosen the thumb bolt beneath
Figure 8.13
the ashlip.
Lift up on the top of the Front, gently pulling out
Figure 8.14
on the bottom. Set aside in a safe location.
Instructions continue for Quartet Front only:
Doors ship attached to the face. If they have been removed,
follow instructions below.
Install one door at a time. Slide the bottom hinge rod into the
lower hinge box hole on the face.
Page 32
Solitaire Front
Quadra-Fire · Sapphire · 250-7233H
Place a washer on the top of the door hinge. Line
Figure 8.15
up the hole in the door hinge and the washer with the hole in
the hinge box of the face. Place a gold-plated hinge pin in
the hole to secure.
Quartet Door Alignment
Doors are properly aligned at the point of manufacture.
However, the possibility exists for them to become out of
alignment during shipping. To correct this occurance, follow
the instructions below.
Back of Quartet Face: Locate the two Allen head
Figure 8.16
bolts connecting the hinge bar to the face. The hinge bar can
be adjusted left or right.
Use a 5/32 in. Allen head wrench and loosen the
Figure 8.17
Allen head bolts. Make necessary adjustment (move hinge to
right or left, for proper fit and operation of doors, and retighten
Allen bolts.
Allen head bolts
on back of Quartet
Face - 2 per side.
Hinge Bar-make
adjustment right
or left.
September 1, 2008