Electrical Installation; Grounding Requirements; Installation - Frigidaire CLCG900FW3 Installation Instructions Manual

Full size laundry center gas & electric
Table of Contents

Advertisement

Available languages

Available languages

ELECTRICAL
INSTALLATION
ALL ELECTRIC Laundry
Centers
The following
are spedfic requirements
for proper and safe electrical installation
of your laundry
center. Failure to follow
these instructions
can create an
electrical
shock and/or a fire hazard.
_This
appliance MUST be properly grounded.
Electrical shock can result if the laundry center is not properly
grounded. Follow the instructions in this manual for proper
grounding.
Do not use an extension cord with this
laundry center. Some extension cords are not designed to
withstand the amounts of electrical current this laundry center
utilizes and can melt, creating electrical shock and/or fire
hazard. Locate the laundry center within reach of the receptacle
for the length power cord to be purchased, allowing some slack
in the cord. Refer to the pre-installation
requirements in this
manual for the proper power cord to be purchased.
_
A U.L. approved
strain relief
must be
installed onto power cord. If the strain relief is not attached,
the cord can be pulled out of the laundry center and can be
cut by any movement of the cord, resulting in electrical shock.
Do nott use an aluminum wired receptacle
with a copper Wired power cord and plug (or vice versa). A
chemical reaction occurs between copper and aluminum and
can cause electrical
shorts.
The proper
wiring
and
receptacle is a copper wired power cord with a copper
wired
receptacle
OR aluminum
wired power
cord with
an aluminum
wired
receptade.
NOTE: Laundry centers operating on a 208 volt power supply
will have longer drying times than laundry centers operating on
a 240 volt power supply.
GROUNDING
REQ UIREMENTS
Non-Canadian ELECTRIC Laundry Center
]
Improper
connection
of the equipment
grounding conductor can result in a risk of electrical shock.
Check with a licensed electrician if you are in doubt as to
whether the appliance is properly grounded.
For a grounded
cord-connected laundry center:
1. The laundry center MUST be grounded. In the event of
malfunction or breakdown, grounding will reduce the risk of
electrical shock by a path of least resistance for electrical
current.
2. If your laundry center is equipped with a power supply cord
having an equipment-grounding conductor and a grounding
plug, the plug MUSTbe plugged into an appropriate, copper
wired receptacle that is properly installed and grounded in
accordance with all local codes and ordinances. If in doubt,
call a licensed electrician.
For a permanently connected laundry center:
The laundry center MUSTbe connected to a grounded metal,
permanent wiring system; or an equipment grounding con-ductor
MUSTbe run with the circuit conductors and connected to the
equipment-grounding
terminal or lead on the appliance.
[
ALL 6AS Laundry
Centers
}
The laundry center is equipped with a three-prong (grounding)
plug for your protection against shock hazard and should be
plugged directly into a properly grounded three-prong receptacle.
Do not cut or remove thegrounding prong from the plug.
Canadian ELECTRIC Laundry Center
}
_lmproper
connection
of the equipment
grounding conductor can result in a risk of electrical shock.
Check with a licensed electrician if you are in doubt as to
whether the appliance is properly grounded.
For a grounded cord connected laundry center:
1. The laundry center MUST be grounded. In the event of
malfunction or breakdown, grounding will reduce the risk of
electrical shock by providing a path of least resistance for
the electrical current.
2. Since your laundry center is equipped with a power supply
cord having an equipment-grounding
conductor
and a
grounding
plug, the plug MUST
be plugged
into an
appropriate
outlet that is properly installed and grounded
in accordance with all codes and ordinances. If in doubt,
call a licensed electrician.
[
NON-CANAD/AN ELECTR/CLaundry Center
J
ELECTRICAL CONNECTIONS FOR A 3 WIRE SYSTEM
,
,
,
,
Remove
the
screw
securing
the
terminal block access cover to the rear
panel and remove cover.
Install a U.L. approved strain relief
connector in the entry hole on the back
panel.
Insert a NEMA 10-30 Type SRDT, U.L. approved power
cord through the strain relief.
Attach the power cord neutral (central wire) conductor to
the silver colored center terminal on the terminal block.
Tighten the screw securely.
GREEN GROUND
SCREW
SILVER TERMINAL
NEUTRAL
GROUND
WIRE