Frigidaire GCET1031FS4 Installation Instructions Manual
Frigidaire GCET1031FS4 Installation Instructions Manual

Frigidaire GCET1031FS4 Installation Instructions Manual

27" (69 cm) wide laundry center washer- dryer
Hide thumbs Also See for GCET1031FS4:
Table of Contents

Advertisement

Available languages

Available languages

27" (69 cm) Wide
LAUNDRY CENTER
Washer-
Dryer
CENTRO DE LAVANDERiA
COMBINE LAVEUSE/SECHUESE
Largeur de 27pounces (69cm)
/
4_1r_
\
PIN 134897400A
(0712)

Advertisement

Table of Contents
loading

Summary of Contents for Frigidaire GCET1031FS4

  • Page 1 27" (69 cm) Wide LAUNDRY CENTER Washer- Dryer CENTRO DE LAVANDERiA COMBINE LAVEUSE/SECHUESE Largeur de 27pounces (69cm) 4_1r_ PIN 134897400A (0712)
  • Page 2: Table Of Contents

    Table Of Contents SUBJECT PAGE Pre-lnstallation Requirements ............................Electrical Requirements ..............................Water Supply Requirements ............................Drain Requirements ............................... Exhaust System Requirements ........................... Gas Supply Requirements ............................Location ................................... Rough-In Dimensions ..............................Mobile Home Installation ............................Unpacking ............................... Electrical Installation ............................... Grounding Requirements .............................
  • Page 3: Pre-Lnstallation Requirements

    PRE-INSTALLATION REQUIREMENTS GASLaundry Center Tools and Materials Required for Installation: 1. Phillips head screwdriver. CIRCUIT- Individual 15 amp minimum branch circuit fused with 2. Channel-lock adjustable pliers. a time delay fuse or circuit breaker. 3. Carpenter's level. POWER SUPPLY-3 wire, 120 volt single phase, 60 Hz, 4.
  • Page 4: Exhaust System Requirements

    EXHAUST SYSTEM REQ UIREMENTS Do not allow combustible materials (for Use only 4 inch (10.2 cm) diameter (minimum) rigid or flexible example: clothing, draperies/curtains, paper) to come in metal duct and approved vent hood which has a swing-out contact with exhaust system.
  • Page 5: Gas Supply Requirements

    The laundry center may be exhausted four (4) ways with rear GAS SUPPLY REQUIREMENTS flush installation: 1. Straight back 1.Installation MUSTconform with local codes, or in the absence 2. Down (8 inch [20.32 cm] length of 4 inch [10.16 cm] rigid of local codes, with the National Fuel Gas Code, ANSI Z223.1 duct and 1 elbow down) (latest edition) or in Canada, the current AN/CGA B149.
  • Page 6: Rough-In Dimensions

    ROUGH-IN DIMENSIONS 25 ¼ IN. (64.13 CM) --14_ 2 I/2 IN. (6.35 CM) 47" 16 ¼ IN. (41.27 CM) GAS SUPPLY PiPE (REAR) , _-_, 1 718 IN. ( 51/41N. (4.76 CM) 13.33 CM) 75 1/2iN. (191.77 CM) ELECTRICAL CONNECTION 43 IN.
  • Page 7: Mobile Home Installation

    MOBILE HOME INSTALLATION 1.Dryer MUST be exhausted outside (outdoors, not beneath the mobile home) using metal ducting that will not support combustion. Metal ducting must be 4 inches (10.16 cm) in diameter with no obstructions. Rigid metal duct is preferred. 2.If dryer is exhausted through the floor and area beneath the mobile home is enclosed, the exhaust system MUST terminate outside the...
  • Page 8: Electrical Installation

    ELECTRICAL INSTALLATION GROUNDING REQUIREMENTS ALL ELECTRICLaundry Centers Non-CanadianELECTRICLaundryCenter Improper connection of the equipment _The following are specific requirements grounding conductor can result in a risk of electrical shock. proper and safe electrical installation of your laundry center. Failure to follow these instructions can create electrical shock Check with a licensed electrician if you are in doubt as to whether and/or a fire hazard.
  • Page 9: 4-Wire Connections

    ELECTRICAL CONNECTIONS ELECTRICAL CONNECTIONS FOR A 3-WIRE SYSTEM FOR A 4-WIRE SYSTEM NON-G4NAD/ANEZECTR/CLaundry Center NON-CANAD/ANELECTR/CLaundry Center 1. Remove the screw securing the Remove the screw securing the terminal block access cover to terminal block access cover to the the rear panel and remove cover. rear panel and remove cover.
  • Page 10: Installation

    INSTALLATION 1. Run some water from the hot and cold faucets to flush the Open the shutoff valve in the gas supply line. water lines and remove particles that might clog up the water valve screens, Test all connections by brushing on a soapy water solution. NEVER TEST FOR GAS LEAKS WITH AN OPEN FLAME.
  • Page 11: Replacement Parts

    REPLACEMENT PARTS 10. Connect the exhaust duct to outside duct work. Use duct If replacement parts are needed for your laundry center, contact tape to seal all joints. the source where you purchased your laundry centen Destroy the carton, plastic bags, and metal 11.
  • Page 12: Franc Ais

    Table matieres SUJET PAGE Avantl'installation ..............................Exigences_lectriques ............................. Exigencesd'alimentation ............................Exigensesdevidange ............................. Exigensesdu circuit d'evacuation ........................14-15 Exigensesd'alimentation en gas .......................... Emplacement du combin_ laveuse/s_cheus ......................Dimensions de I'emplacement ..........................Installation dans une maison mobile ........................D_ballage ................................. Installation _lectrique ............................Exigencesde mise a la terre ...........................
  • Page 13: Avantl'installation

    CORDOND'ALIMENTATION - Le combin_ laveuse/s_cheuse AVANT L'INSTALLATION gaz est d'un cordon d'alimentation _lectrique _ 3 ills de 120 volts. Outils et materiel requis pour I'installation I. Tournevis _ pointe cruciforme 2. Pinces multiprise REMARQUt= : II ne faut en aucun cas retirer 3.
  • Page 14: Exigensesdu Circuit D'evacuation

    La secheuse dolt @treconnect_e _ une bouche d'_vacuation EVA CUATION DE L'AIR vers I'ext_rieur du b&timent ou de I'immeuble. Vou s devez Utiliser uniquement une conduite en m_tal rigide ou flexible de inspecter r6guli_rement 1'6vent ext6rieur et enlever toute 10,2 cm (4 po) de diametre (minimum) ainsi qu'une grille de sortie accumulation de charpie autour de I'_vent et dans la cavite du approuv@e pourvue de clapets qui s'ouvrent Iorsque la s@cheuse conduit d'_vacuation.
  • Page 15: Emplacement Du Combin_ Laveuse/S_Cheus

    L'6vacuation ducombine laveuse/s6cheuse paruncircuit EMPLA CEMENT DU COMBINEE LA VEUSE/SECHEUSE d'6vacuation arri_re peutsefairedequatre (4)facons: NE PAS INSTALLER COMBINE LAVEUSE/SECHEUSE : En ligne droite. 1. Dans un endroit expos_ a un _coulement d'eau ou aux 2. Vers le bas (8 pounces (20,32 cm) de Iongueur pour un conditions atmosph_riques.
  • Page 16: Dimensions De I'emplacement

    Dimensions de I'emplacement 25 I/4IN. (64.13 CM) -- 2 1/2 IN. (6.35CM) 47" 161_ IN, (41.27 CM) TUYAU D'ALIMENTATION EN GAZ (ARRIERE} 12I/2 _N.--_I _ 9 318 IN. v i (23.81,cM) (31.75 CM) 1 7/8 IN. (4.76 CM) 751/2IN. (191.77 CM) CONNEXCIONS ELECTRIQUES ©...
  • Page 17: Installation Dans Une Maison Mobile

    iNSTALLATION DANS UNE MAiSON MOBILE 1. L'_vacuation de la s@cheuseDOITse faire a I'exterieur (_ Le combin6 est conc;ue conform6ment I'ext_rieur et non pas au-dessous de la maison mobile) un USAGE DOMESTIQUE la norme ANSI Z 21.5.1 pour I'aidedeconduitenm_talinflammable. Lesconduitsen seulement. m_tal doivent avoir 4 pounces (10,16 cm) de diametre sans obstructions.
  • Page 18: Installation

    INSTALLATION ELECTRIQUE Pour brancher la s6cheuse en permanence : Lacombin6 DOITCtre branch6e a une installation m6tallique misea laterreen permanence; sinon, un conducteur de raise TOUS combinees/aveude/s_cheusesf-LECTR/OUES la terre de l'appareil doit suivre lesconducteurs du circuit et 6tre branchea la borneou a la connexion de misea laterre Les mises en garde qui suivent de I'appareil.
  • Page 19: Installation

    4. Fixer l econducteur neutre (conducteur central) d ucordon 5. Fixer le fil de terre vert du cordon d'alimentation au boitier d'alimentation alaborne centrale a rgent_e d upanneau d e de la s_cheuse a I'aide de la vis de mise a la terreverte. branchement.
  • Page 20: Pi_Cesde Rechange

    b.Brancher untuyausemi-rigide ouapprouv6 de1,27cm 10. Reliez les conduits d'6vacuation d'air conduit d'_vacuation (1/2 po) de diam_tre int_rieur entre la conduite ext6tieur. Utilisez un ruban adh6sif pour conduits pour d'alimentation engaz etletuyau de0,96cm(3/8po)situe sceller les joints. surI'arri_re de la s_cheuse. Utiliser un r6ducteur d e 11.

This manual is also suitable for:

Gcet1031fs1Gcet1031fs2Fez831cfs1Mex731cfs2

Table of Contents