Install Water Tank (P) (if equipped):
• A factory installed water tank is available in some
regions. An optional water tank kit is available for all
regions.
• If water tank was previously installed on machine, read
these instructions to verify that installation is correct. Fol-
low all WARNINGS for installation and use of the Water
Tank.
• Verify the contents of the Water Tank Kit See Diagram at
right.
. FS 513 Only: Temporarily remove the right hand (same
side of machine as engine starter rope) NUT from Lifting
Eye (O). See diagram at right.
. FS 513 Only: Install CLAMP supplied in Water Tank Kit
(P), and then reinstall the NUT. See diagram at right.
. FS 513 Only: Torque as specified below, and diagram
at right.
Torque Lifting Eye NUT to 83 N-m (61 lb-ft) mini-
Torque NUT as specified, else failure of LIFTING EYE
(O) could occur. Injury or death could occur if LIFT-
ING EYE fails while lifting machine.
NOTICE
mum.
WARNING!