UNSETTING THE SYSTEM

PIN + ent
Galaxy 520 V5.00
15.49 MON 18 Nov
PIN + ent
4 ALARMS
[<] [>] to View
CALL MANAGER
RESET REQUIRED
CALL ENGINEER
RESET REQUIRED

Normal Entry

Unsetting starts immediately when the FINAL door is opened or an
ENTRY zone is activated. The sounder pulses slowly and the user must
go directly to the keyprox and present a valid keytag or card to the prox
reader to unset the system.
If using a keypad enter a valid PIN, followed by A>, <B or ent.
Users with group choice, will access the UNSET screen following PIN
entry. This permits the user to unset specific groups. To return to the
SET screen press ent.

Straying From the Entry Route

Go directly to the keypad when entering the building. If the user strays
into a protected area and activates a zone, an alarm will occur. The police
may be called out and the system will have to be reset.

Slow Entry

Enter a valid PIN before the entry time expires. If the entry time expires
before a valid PIN is entered, then an alarm will occur. The sounder
begins to pulse quickly when 75% of the entry time has elapsed indicating
time is running short.

Cancelling Alarms

To cancel an alarm, enter a valid PIN followed by ent at the keypad. The
keypad displays details of the zone activated. When more than one zone
is activated, details can be viewed using A > or < B. Press ent to return to
the banner. Certain types of alarms, once cancelled, require a code with
the appropriate reset authorisation to be entered. The system prompts
for a valid reset code by displaying Manager Reset Required or
Engineer Reset Required on the keypad.

Manager Reset

Entering a manager type PIN followed by ent, resets the system following
an alarm activation.

Engineer Reset

Certain types of alarm require an engineer to visit the site and, after
investigation, reset the system. In such cases, the system cannot be
reset until the engineer reset has been carried out.

Unsetting with Proximity Cards

If any of the groups assigned to the card are set, then swiping the MAX,
keyprox or access control reader with a card unsets the groups. Group
choice and dual focus operation, where implemented will apply as per
setting instructions.
8