Download Print this page

American Standard Exposed Wall Mount Sink Faucet with Gooseneck Spout 7293.152 Installation Instructions page 2

Exposed wall mount sink faucet and gooseneck spout with everclean finish

Advertisement

FINISH INSTALLATION
Apply thread sealant or teflon tape to SUPPLY NIPPLES (1).
Slide COUPLING NUTS
(2)
Thread ESCUTCHEONS
(4)
Thread INLET SHANKS
(3)
between INLET SHANK
(3)
Insert RUBBER WASHERS
Attach VALVE
(5)
to INLET SHANKS (3).
Tighten both COUPLING NUTS
1
TEST FAUCET
Remove AERATOR (1).
Turn HANDLES TO OFF POSITION.
Slowly turn water supplies on and check all connections for leaks.
Operate HANDLES to flush water lines thoroughly.
Turn HANDLES to OFF position and replace AERATOR (1).
Thread ESCUTCHEONS against finished wall.
SERVICE
To change direction of handle rotation, proceed as follows:
Turn HANDLE to OFF position.
Remove HANDLE SCREW and HANDLE.
Remove SPRING CLIP (1).
Lift STOP WASHER (2), turn 90 and replace.
Replace SPRING CLIP (1).
Replace HANDLE and HANDLE SCREW.
AERATOR may accumulate dirt causing distorted and reduced water flow.
Remove AERATOR and rinse clean.
If spout drips, operate handles several times from OFF to ON position.
Do not force - handles turn only 90 .
onto INLET SHANKS (3).
fully onto INLET SHANKS (3).
onto SUPPLY NIPPLES (1). Distance
outlets must be 8" to match the VALVE (5).
(6)
into INLET SHANK (3).
(2)
firmly.
4
2
3
6
1
2
5
90
1

Advertisement

loading

This manual is also suitable for:

7293.2527293.152