Schedule Settings – Defaults
This thermostat is preprogrammed with a schedule that is recommended
by EnergyStar™. The schedule is designed to lower energy costs
year-round.
The default schedule settings are:
Time
Morn
6:00 am
Day
8:00 am
Eve
6:00 pm
Nite
10:00 pm
User Settings – Defaults
During any program changes the display returns back to the operating
display if a button has not been pushed in 10 seconds.
The temperature scale is set to Fahrenheit.
Night light is on.
The first stage differential is 1 °F.
The second stage differential (RS6220) is 2 °F.
The second stage delay is 20 minutes.
Third stage delay (RS6320) is 20 minutes.
Auto changeover is enabled.
Auto changeover deadband is 3 °F.
Filter reminder length is off.
Temperature offset is 0 degrees.
The HI heat limit is 90 °F (32 °C).
The LO cool limit is 45 °F (7 °C)
The operation mode is OFF.
The fan setting is Auto.
The keypad has no password protection.
Refer to the pop up wizard section in the installation manual for a
complete list of factory defaults and contractor settings.

Emergency Heat

Your system may include Emergency Heat. The RS6220 and RS6320
thermostats have an emergency heat capability for multi stage heat
pump systems. To determine if your system is capable of using
emergency heat contact your contractor. Use the
the EMER mode. An E will be displayed with the Heat symbol. This
mode is used to bypass the heat pump when it needs servicing or when
it cannot keep up with the heat demand.
Cooling °F
Heating °F
78
70
85
62
78
70
82
62