Remote Blower Installation - Thermador An American Icon PH30ZS Installation Instructions Manual

Ph series wall hood
Hide thumbs Also See for An American Icon PH30ZS:
Table of Contents

Advertisement

Available languages

Available languages

Wiring the Hood with an
Integral Motor
WARNING
Turn off electricity at the service panel
before wiring the unit. (See Safety
Instructions, Page 2).
1. Remove the j-box cover.
2. Connect the VTN1000Q molex plug connector to
the connector present inside the hood as shown
in Figure 13.
3. Install 1/2" conduit connector in j-box.
From Ventilator
From Control Panel
Figure 13
4. Run black, white, and green wires (#12 AWG) in
1/2" conduit from power supply to J-box.
5. Connect the power supply wires to the hood
wires in the following order: black to black, white
to white, and green wire to green ground screw
on chasis. Use spring type wire nuts supplied.
(Lost or missing wire nuts should only be
replaced with: Spring type wire nuts, rated for a
minimum of (2) # 18ga wires and maximum of
(4) #14ga wires, UL & CSA rated to 600V and
302 deg. F./150 deg. C).
6. Close J-box cover. Check to see that light bulbs
are secure in their sockets. Replace filters as
described in the Care & Use Manual. Turn power
on at service panel. Check operation of the
hood.

Remote Blower Installation

The PHZ hood models are designed to work with
VTR600R, VTR1000Q, and VTR1400Q remote
blowers. For installation instructions see the
instructions supplied with the blower unit.
Wiring the Hood with a
Remote Blower:
Figure 14
1. Remove the J-box cover.
2. Install 1/2" conduit connectors.
3. Run black, white, and green wires (#12 AWG) in
1/2" conduit from power supply to j-box.
4. Connect the power supply wires to the hood
wires in the following order: black to black,
white to white, and
screw on chassis. Use spring type wire nuts
supplied. (Lost or missing wire nuts should
only be replaced with: Spring type wire nuts,
rated for a minimum of (2) # 18ga wires and
maximum of (4) #14ga wires, UL & CSA rated
to 600V and 302 deg. F./150 deg. C).
5. Connect the "pigtail" to the connector inside the
junction box.
6. Run five wires (#14 AWG) in 1/2" conduit from
the remote blower to the second conduit
connector.
7. Connect the remote ventilator to the pigtail
wires (Step 6) as per Figure 14. Connect the
remote blower green (ground) wire to the ground
screw in the junction box.
8. Close junction box cover. Check that all light
bulbs are secure in their sockets. Install filters.
Turn power on at service panel, and check
lights and blower operation per Care & Use
Manual.
Page 11
greenwire
to green ground

Advertisement