JVC AV-29MXP6/V Service Manual page 31

Flat colour television
Table of Contents

Advertisement

Measuring
Item
instrument
V. POSITION
Signal
generator
Remote
control unit
V. SIZE
Signal
generator
Remote
control unit
Screen
size 92%
H. POSITION
Signal
generator
Remote
control unit
C
Test point
Adjustment part
[4. DEF]
1. V-SHIFT
A
B
[4. DEF]
3. V-SIZE
Picture
size 100%
[4. DEF]
4. H-CENT
D
Description
PAL V. POSITION
(1) Receive a circle pattern signal of vertical frequency
50Hz (PAL).
(2) Select 4. DEF from the SERVICE MODE.
(3) Select <1. V-SHIFT>.
(4) Set the initial setting value of <1. V-SHIFT>.
(5) Adjust <1. V-SHIFT> to make "A = B".
(6) Press the [OK] key to memorize the set values.
NTSC V. POSITION
(1) Receive a circle pattern signal of vertical frequency
60Hz (NTSC).
(2) Follow the same step 2 to 6 as in PAL V. POSITION.
PAL V. SIZE
(1) Receive a PAL crosshatch signal.
(2) Select 4. DEF from the SERVICE MODE.
(3) Select <3. V-SIZE>.
(4) Set the initial setting value of <3. V-SIZE>.
(5) Adjust <3. V-SIZE> to make the vertical screen size
to 92% of the picture size.
(6) Press the [OK] key to memorize the set values.
NTSC V. SIZE
(1) Receive a NTSC crosshatch signal.
(2) Follow the same step 2 to 6 as in PAL V. SIZE.
PAL H. POSITION
(1) Receive a PAL circle pattern signal.
(2) Select 4. DEF from the SERVICE MODE.
(3) Select <4. H-CENT>.
(4) Set the initial setting value of <4. H-CENT>.
(5) Adjust <4. H-CENT> to make "C = D".
(6) Press the [OK] key to memorize the set values.
NTSC H. POSITION
(1) Receive a NTSC circle pattern signal.
(2) Follow the same step 2 to 6 as in PAL H. POSITION.
(No.YA476)1-31