JVC AV-29MXP6/V Service Manual page 29

Flat colour television
Table of Contents

Advertisement

4.9
ADJUSTMENT PROCEDURE
4.9.1 CHECK ITEM
Measuring
Item
instrument
B1 VOLTAGE
DC voltmeter
[AV-21MXP6/V,
AV-25MXP6/V]
Remote
control unit
B1 VOLTAGE
DC voltmeter
[AV-29MXP6/V]
Remote
control unit
HIGH VOLTAGE HV voltmeter
Remote
control unit
IF VCO
Remote
control unit
IF SERVICE MENU
1. VCO
2. DELAY POINT
1 : SELECT
DISPLAY : EXIT
Test point
Adjustment part
CN00B
connector
1-pin:TP-B1
3-pin:TP-E
[MAIN PWB]
CN00X
connector
1-pin:TP-B1
5-pin:TP-E
[MAIN PWB]
CRT anode
Chassis GND
MODEL
VOLTAGE
AV-21MXP6/V
28.5kV ( 1.5kV)
AV-25MXP6/V
30.5kV ( 1.5kV)
31.5kV (+1kV - 1.5kV)
AV-29MXP6/V
[1.IF]
1.VCO
Receiving frequency
VCO (CW)
.
MHz
TOO HIGH
ABOVE REFERENCE
JUST REFERENCE
BELOW REFERENCE
TOO LOW
DISPLAY : EXIT
(1) Receive any broadcast.
(2) Connect a DC voltmeter to 1-pin and 5-pin of
connector.
(3) Make sure that the voltage is DC134.5V ±2.0V.
(1) Receive any broadcast.
(2) Connect a DC voltmeter to 1-pin and 5-pin of
connector.
(3) Make sure that the voltage is DC134.5V ±2.0V.
(1) Receive any broadcast.
(2) Connect the earth clip of HV voltmeter to chassis
GND.
(3) Connect the probe of HV voltmeter to CRT anode.
(4) Make sure that the voltage is table in the left.
NOTE:
• Remove the probe before removing the earth clip.
• Under normal conditions, no adjustment is required.
• Confirmation adjustment.
(1) Select 1.IF from the SERVICE MODE.
(2) Select <1.VCO>
(3) Receive any broadcast.
(4) Check the
REF. and BELOW REF.