MAINTENANCE
BLENDED PHOSPHATE TREATMENT
SYSTEM (OPTIONAL)
The Blended Phosphate Water Treatment System
reduces mineral scale by introducing a measured
amount of polyphosphate into the water. Cartridges
supplied have a usage rating of 100,000 gallons
(378,541 liters) of water. When the cartridge is
depleted
use
the
replacement:
1. Shut off electrical power to the heater.
2. Shut off water supply and open drain valve to
remove water in piping.
3. Loosen canister using wrench attached.
4. Remove canister and discard depleted cartridge.
5. Using a clean damp cloth, wipe interior of
canister clean.
NOTE: Make sure O-ring seal is properly placed in
canister.
6. Reverse procedure to reinstall.
Form No. EBOOSTERM-0406
following
procedure
If service is required on this unit, contact your
Authorized Hatco Service Agent, or contact the
Hatco Service Department at 800-558-0607 or
414-671-6350; fax 800-690-2966 or International
fax 414-671-3976.
for
This product has no "user" serviceable parts. To
avoid damage to the unit or injury to personnel,
use only Authorized Hatco Service Agents and
Genuine Hatco Replacement Parts when service
is required.
Genuine Hatco Replacement Parts are specified
to operate safely in the environments in which
they are used. Some aftermarket or generic
replacement
characteristics that will allow them to operate
safely in Hatco equipment. It is essential to use
Hatco Replacement Parts when repairing Hatco
equipment. Failure to use Hatco Replacement
Parts may subject operators of the equipment to
hazardous electrical voltage, resulting in
electrical shock or burn.