Heat Dissipation; Environmental Specifications - Dell PowerEdge R415 Technical Manual

Hide thumbs Also See for PowerEdge R415:
Table of Contents

Advertisement

Dell
Feature
Hot-plug Capability
Output Power
Efficiency
20% to 100% Load
Energy Star Certification &
Compliance
1
Does not include the power supply handle or ejection tab.

4.3 Heat Dissipation

Table 5 details heat dissipation for the PowerEdge R415.
Description
Wattage
Voltage

Heat Dissipation

4.4 Environmental Specifications

Table 6 summarizes the environmental specifications for the PowerEdge R415.
Temperature
Operating
Storage
Relative Humidity
Operating
Storage
Maximum Vibration
Operating
Storage
PowerEdge R415 Technical Guide
Non-Redundant Power
Supply
ambient operating range, the
inrush current may reach 25A
per power supply for 10ms or
less.
No
480W
82–85% @115VAC
82–85% @ 230VAC
80+ Bronze
Heat Dissipation
Table 5.
Non Redundant Power Supply
480W
100–240VAC, 50–60Hz, 7.5–3.8
1637 BTU/hr maximum

Environmental Specifications

Table 6.
10° to 35°C (50° to 95°F) with a maximum temperature
gradation of 10°C per hour
Note: For altitudes above 2950 feet, the maximum operating
temperature is derated 1°F/550 ft.
-40° to 65°C (-40° to 149°F) with a maximum temperature
gradation of 20°C per hour
20% to 80% (noncondensing) with a maximum humidity gradation
of 10% per hour
5% to 95% (noncondensing) with a maximum humidity gradation
of 10% per hour
0.26Grms at 5–350Hz in operational orientations
1.87Grms at 10–500Hz in all orientations
Redundant Power Supply
ambient operating range, the
inrush current may reach 25A
per power supply for 10ms or
less.
Yes
500W
86–90% @115VAC
88–92% @ 230VAC
80+ Silver
Redundant Power Supply
500W
100–240VAC, 50–60Hz, 7.5–3.8
1706 BTU/hr maximum
24

Advertisement