Preset Save And Recall Functions; Power Functions; Special Commands - Hall Research Technologies Genesis Digital HSM-04-04 User Manual

Dmi / dvi matrix switch series
Table of Contents

Advertisement

User's Manual
Command:
Response:
Variations:
Command:
Response:
Command:
Response:

4.2 Preset Save and Recall Functions

Command:
Response:
Command:
Response:

4.3 Power Functions

Command:
Response:
This command can take up to 10 seconds to complete. Upon powering up the unit will recall
the previous state of each output prior to powering off and restore each connection.
Command:
Response:
Variation:
Command:
Response:

4.4 Special Commands

Command:
Response:
12
COn,m<cr>
stands for Connect Output n to input m
COn,m<cr>
COn <cr>
stands for Connect Output n Query
COn,m<cr>
CO*,m<cr>
stands for Connect All Outputs to input m
CO1,m<cr>
CO2,m<cr>
CO3,m<cr> (for 4x4 matrices only)
CO4,m<cr> (for 4x4 matrices only)
PRx<cr>
stands for Preset Recall. x = preset 1~ 8
CO1, m
<cr>
1
CO2, m
<cr>
2
CO3, m
<cr> (for 4x4 matrices only)
3
CO4, m
<cr> (for 4x4 matrices only)
4
PSx<cr>
stands for Preset Save. x = preset 1~ 8
None (the current tie pattern is saved in EEPROM)
PW1<cr>
stands for Power On
PW1<space><cr>
CO1, m
<cr>
1
CO2, m
<cr>
2
CO3, m
<cr> (Only for 4x4 matrices)
3
CO4, m
<cr> (Only for 4x4 matrices)
4
Important Note on Power ON Command
PW0<cr>
stands for Power Off
PW0<cr>
PW<cr>
stands for Power Query
PWx<cr><lf>
x=0 (off), or 1 (on)
FB<cr>
stands for Firmware Boot
Depends on power state when the command was issued. This command is
equivalent to unplugging the power supply and reconnecting it.

Advertisement

Table of Contents
loading