Download Print this page

Zanussi ZC 550 ML User Manual page 8

Gas cooker zc 550 ml; zc 550 mh

Advertisement

14
air adjusting
GRILL BURNER
-
Loosen the screw fixing the Venturi.
-
Move the pipe left or right till getting the right adjustment
-
Tighten the fixing screw.
ADJUSTING OF MINIMUM FLOW
HOB BURNERS
-
Turn the knob to left on position min-flow
-
Light the burner
-
Pull out the knob and adjust the min-flow by the screw driver fixing it in the
axle of the tap: by screwing the flow is diminished - unscrewing it will increase.
-
For butane or propane gas the screw must be well tightened.
-
Try several times to pass from max-flow to min-flow the flame shouldn't die on.
fixing screw
15
OVEN BURNER
− Remove the oven bottom.
− Light the burner (knob on position max-flow or 8) and leave the oven door closed
for about 10 min.
− Turn the knob slowly to position min-flow or 1.
− Pull out the knob for adjusting of min-flow
− Introduce the screwdriver in the tap's rod at taps without thermostat or near the
rod in the left part at taps with thermostat, until to getting a 5mm flame.
− For butane or propane gas the screw must be well tightened.
− The flame shouldn't die out when closing normally the oven door. Try several
times.
or
GRILL
The grill burner cannot be adjusted for economical flow.
BURNERS
NOM. POWER
TYPE OF GAS
PRESSURE
(kW)
(mbar)
NATURAL GAS G 13
RAPID
2,60
NATURAL GAS G 20
LPG
G 30
NATURAL GAS G 13
SEMI-RAPID
1,70
NATURAL GAS G 20
LPG
G 30
NATURAL GAS G 13
AUXILIARY
0,95
NATURAL GAS G 20
LPG
G 30
NATURAL GAS G 13
2,55
NATURAL GAS G 20
OVEN
LPG
G 30
NATURAL GAS G 13
2,00
NATURAL GAS G 20
GRILL
LPG
G 30
NOZZLE
DIAM.
(mm)
13
1,40
20
1,30
30
0,90
13
1,20
20
1,05
30
0,75
13
0,85
20
0,80
30
0,55
13
1,50
20
1,35
30
0,92
13
1,25
20
1,15
30
0,80

Advertisement