Setting the FortiSwitch-5003A configuration switch
14
To change or verify the SW3 switch settings
To complete this procedure, you need:
A FortiSwitch-5003A board
A tool for changing the SW3 switch setting (optional)
An electrostatic discharge (ESD) preventive wrist strap with connection cord
Caution: FortiSwitch-5003A boards must be protected from static discharge and physical
shock. Only handle or work with FortiSwitch-5003A boards at a static-free workstation.
Always wear a grounded electrostatic discharge (ESD) preventive wrist strap when
handling FortiSwitch-5003A boards.
1
Attach the ESD wrist strap to your wrist and to an ESD socket or to a bare metal
surface on a chassis or frame.
2
If you have installed the FortiSwitch-5003A board in a chassis, remove it.
For removal instructions, see
3
Use
Figure 9
to locate SW3 on the FortiSwitch-5003A board.
Figure 9: Location of SW3 on the FortiSwitch-5003A board
FortiGate-5003A
board (top view)
FortiGate-5003A
Front Faceplate
4
If required, change SW3 to the required setting (see
5
Insert the FortiSwitch-5003A board into a chassis and verify that the board starts
up and operates correctly.
For inserting instructions, see
"Removing a FortiSwitch-5003A board" on page
Figure 7
"Inserting a FortiSwitch-5003A board" on page
FortiSwitch-5003A System Guide
Hardware installation
18.
Location of SW3
ON
1
2
3
4
and
Figure
8).