CDA SC309 Manual For Installation, Use And Maintenance page 13

Gas oven
Table of Contents

Advertisement

REGULATION OF THE MINIMUM FLAME
This needs to be done only for the oven burner (the grill is a fixed capacity) by acting
on the thermostat.
Considering that in the minimum position the flame must have a length of about 4
mm and must remain lit even with a brusque passage from the maximum position to
that of minimum.
The flame adjustment is done in the following way:
Light the oven burner by turning the knob on position
Let the oven pre-heat for about 10 minutes, then take the knob to position
(minimum) to operate at by-pass flow.
Remove the thermostat knob and by means of a thin screwdriver pass by the hole in
the facia panel to unscrew of 3 turns the by-pass screw G (fig. 12)
Slowly tighten the by-pass screw G (fig. 12) until you get a flame of 3-4 mm long.
Turn off the burner and reassemble the knob.
After regulation (always with oven hot and the oven door closed) check the stability
of the flame with a passage from the maximum to minimum position.
The grill is a fixed capacity and does not be adjusted.
N.B.: For Liquid gas (G 30/G 31) the screw G must be tightened thoroughly.
Figure 12
G