Engine Fails To Operate; Cold Engine Fails To Start - Yamaha 60C Owner's Manual

Table of Contents

Advertisement

60/70
q
1
2
q
w
w
216011
90
216012
EMN32311

ENGINE FAILS TO OPERATE

If battery voltage is low or in the unlikely
event of an ignition system malfunction,
the engine speed may become erratic or
the engine may stop. In such a case, dis-
connect the connection on the yellow
cord (emergency circuit) to return to port.
w
When the connection is disconnected, the
idling and low speeds are slightly higher
than normal. Use care when starting off
or stopping.
cC
Follow this procedure only in an emer-
gency and just long enough to return to
port for repairs.
1 CDI unit
2 Yellow cord
EMU00955*

COLD ENGINE FAILS TO START

If a cold engine fails to start for prime
start model, use the following procedure.
w
When starting or operating the engine,
do not touch the ignition coil, high volt-
age wire, spark plug cap or other electri-
cal parts carrying high voltage. Keep
loose clothing and other objects away
from the engine when starting it with an
emergency starter rope. An unguarded
rotating flywheel is very dangerous. Do
not attempt to replace the top cowling
when the engine is running. Proceed at
once to the nearest port to get the engine
repaired. Take care to prevent water
splashing onto the flywheel.
5-8