4.5

Installation

The mains plug/socket must be freely accessible once the
miniBar has been installed.
200 cm²
20 mm
IMPORTANT:
Please follow the installation details below
carefully. Guarantee is valid for products
installed as described only.
1. The refrigerator must be level both directions.
2. There should be 20mm clearance to the wall.
3. Ventilation must be provided as shown in
alternatives A, B, C or D.
4. The ventilation duct must at least measure
105mm x the width of the refrigerator.
5. Only the entire cooling unit must project into
the duct as shown.
6 Air passing through the duct must not be
preheated by any source of heat.
7. Ventilation grills, if used, must have openings
of at least 200cm² each.
5